S-35399A03-J8T2G Seiko Instruments, S-35399A03-J8T2G Datasheet - Page 23

Real Time Clock 2-wire Real Time Clock

S-35399A03-J8T2G

Manufacturer Part Number
S-35399A03-J8T2G
Description
Real Time Clock 2-wire Real Time Clock
Manufacturer
Seiko Instruments
Datasheet

Specifications of S-35399A03-J8T2G

Supply Voltage (max)
3 V
Supply Voltage (min)
1.3 V
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Rtc Bus Interface
Serial
Supply Current
0.34 uA
Package / Case
SOP-8
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Rev.2.0
*1. If users clear INT1AE/INT2AE once; “L” is not output from the
These are selectable for the output mode for
Alarm interrupt, the output of user-set frequency, per-minute edge interrupt output, minute-periodical interrupt output 1. In
the
also selectable.
To swith the output mode, use the status register 2. Refer to “ 3. status register 2 ” in “ Configuration of Register ”.
When switching the output mode, be careful of the output status of the pin. Especially, when using alarm interrupt/output of
frequency, switch the output mode after setting “00h” in the INT1/INT2 register. In 32.768 kHz output/per-minute edge
interrupt output/minute-periodical interrupt output, it is unnecessary to set data in the INT1/INT2 register for users.
Refer to the followings regarding each operation of output modes.
1. Alarm interrupt output
INT
Alarm interrupt output is the function to output “L” from the
come. If setting the pin output to “H”, turn off the alarm function by setting “0” in INT1AE/INT2AE in the status register 2.
To set the alarm time, set the data of day of the week, hour, minute in the INT1/INT2 register, set the data of year, month,
day in the alarm expansion register 1 or 2. Refer to “4. INT1 register and INT2 register” and “9. Alarm expansion
register 1 and alarm expansion register 2” in “ Configuration of Register” .
Alarm setting of “Y (year), M (month), D (day), W (day of the week), H (hour), m (minute)”
within a period when the alarm time matches real-time data.
INT
1
,
_00
INT1 pin/INT2 pin
1
INT1AE/INT2AE
INT
Real-time data
pin output mode, in addition to the above modes, minute-periodical interrupt output 2 and 32.768 kHz output are
Y (year), M (month), D (day), W (day of the week)
2
Pin Output Modes
Status register 2 setting
• INT1 pin output mode
• INT2 pin output mode
32kE = 0, INT1ME = INT1FE = 0
INT2ME = INT2FE = 0
Change by program
H h (m − 1) m 59 s
Alarm time matches
Second
Figure 24 Alarm Interrupt Output Timing (1/2)
Real-time data
Minute
mx
INT1 register
INT2 register
INT
Seiko Instruments Inc.
1
Hour Week
Hx
and
H h 00m 00 s
Period when alarm time matches
Change by program
INT
Comparator
Wx
OFF
2
Alarm expansion register 1
Alarm expansion register 2
INT /
pins;
Day
Dx
INT /
1
INTx register alarm enable flag
• AxHE = AxmE = AxWE = "1"
Alarm expansion register x alarm enable flag
• AxYE = AxME = AxDE = "1"
01 s
INT
1
Month
INT
Mx
2
pin, at the alarm time which is set by user has
2
Change by program
pin by setting INT1AE/INT2AE enable again,
Year
Yx
*1
2-WIRE REAL-TIME CLOCK
59 s
Alarm interrupt
H h (m + 1) m 00 s
S-35399A03
23

Related parts for S-35399A03-J8T2G