COM20020I-HT SMSC, COM20020I-HT Datasheet - Page 55

no-image

COM20020I-HT

Manufacturer Part Number
COM20020I-HT
Description
Network Controller & Processor ICs ARCNET Contrllr
Manufacturer
SMSC
Datasheet

Specifications of COM20020I-HT

Product
Controller Area Network (CAN)
Number Of Transceivers
1
Data Rate
5 Mbps
Supply Voltage (max)
5.5 V
Supply Voltage (min)
4.5 V
Supply Current (max)
40 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Package / Case
TQFP-48
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
COM20020I-HT
Manufacturer:
Microchip Technology
Quantity:
10 000
SMSC COM20020I 3.3V Rev.E
5Mbps ARCNET (ANSI 878.1) Controller with 2K x 8 On-Chip RAM
D0-D7
A0-A2
DIR
nDS
nCS
CASE 2 PLCC Package: Must be RBUSTMG bit = 1,
**
Note 1:
Note 2:
*
Figure 18 - Non-Multiplexed Bus, 68xx-Like Control Signals; Read Cycle
T
T
T
T
t10
t11
ARB
ARB
ARB
opr
t1
t2
t3
t4
t5
t6
t7
t8
t9
t8 is measured from the latest active (valid) timing among nCS, nDS, A0-A2.
is the period of operation clock. It depends on CKUP1 and CKUP0 bits
is the Arbitration Clock Period
is identical to T
is twice T
The Microcontroller typically accesses the COM20020 on every other cycle.
Therefore, the cycle time specified in the microcontroller's datasheet
should be doubled when considering back-to-back COM20020 cycles.
Address Setup to nDS Active
Address Hold from nDS Inactive
nCS Setup to nDS Active
nCS Hold from nDS Inactive
Cycle Time (nDS Low to Next Time Low)
Read cycle for Address Pointer Low/High Registers occurring after an access
to Data Register requires a minimum of 5T
the leading edge of the next nDS.
DIR Setup to nDS Active
DIR Hold from nDS Inactive
nDS Low to Valid Data
nDS High to Data High Impedence
nDS Low Width
nDS High Width
TQFP Package: Must be BUSTMG pin = LOW or RBUSTMG bit =1
opr
if SLOW ARB = 1
opr
t1
if SLOW ARB = 0
t5
CASE 2: RBUSTMG bit = 1
t3
Parameter
DATASHEET
Page 55
t8
VALID
ARB
from the trailing edge of nDS to
t10
t6
VALID DATA
4T
min
ARB
100
10
10
30
-5
-5
0
0
0
*+30
max
60**
20
t9
t2
t7
t4
Note 2
t11
units
nS
nS
nS
nS
nS
nS
nS
nS
nS
nS
nS
Revision 09-11-06

Related parts for COM20020I-HT