MT8888CE1 Zarlink, MT8888CE1 Datasheet - Page 10

no-image

MT8888CE1

Manufacturer Part Number
MT8888CE1
Description
DTMF TXRX 3.58MHz CMOS 5V 20-Pin PDIP Tube
Manufacturer
Zarlink
Datasheet

Specifications of MT8888CE1

Package
20PDIP
Operating Frequency
3.58 MHz
Typical Supply Current
7 mA
Typical Operating Supply Voltage
5 V
Minimum Operating Supply Voltage
4.75 V
Maximum Operating Supply Voltage
5.25 V

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MT8888CE1
Manufacturer:
ZARLINK
Quantity:
23
The lookup table contains codes which are used by the switched capacitor D/A converter to obtain discrete and
highly accurate DC voltage levels. Two identical circuits are employed to produce row and column tones, which
are then mixed using a low noise summing amplifier. The oscillator described needs no “start-up” time as in other
DTMF generators since the crystal oscillator is running continuously thus providing a high degree of tone burst
accuracy. A bandwidth limiting filter is incorporated and serves to attenuate distortion products above 8 kHz. It can
be seen from Figure 8 that the distortion products are very low in amplitude.
8.0
In certain telephony applications it is required that DTMF signals being generated are of a specific duration
determined either by the particular application or by any one of the exchange transmitter specifications currently
existing. Standard DTMF signal timing can be accomplished by making use of the Burst Mode. The transmitter is
capable of issuing symmetric bursts/pauses of predetermined duration. This burst/pause duration is 51 ms±1 ms,
which is a standard interval for autodialer and central office applications. After the burst/pause has been issued, the
appropriate bit is set in the Status Register indicating that the transmitter is ready for more data. The timing
described above is available when DTMF mode has been selected. However, when CP mode (Call Progress mode)
is selected, the burst/pause duration is doubled to 102 ms ±2 ms. Note that when CP mode and Burst mode have
been selected, DTMF tones may be transmitted only and not received. In applications where a non-standard
burst/pause time is desirable, a software timing loop or external timer can be used to provide the timing pulses
when the burst mode is disabled by enabling and disabling the transmitter.
Burst Mode
Figure 10 - Spectrum Plot
Zarlink Semiconductor Inc.
MT8888C
10
Scaling Information
10 dB/Div
Start Frequency = 0 Hz
Stop Frequency = 3400 Hz
Marker Frequency = 697 Hz and
1209 Hz
Data Sheet