SM1212E433 Semtech, SM1212E433 Datasheet - Page 42

no-image

SM1212E433

Manufacturer Part Number
SM1212E433
Description
RF Module For SX1212
Manufacturer
Semtech
Series
-r
Type
Transceiver, ISMr
Datasheets

Specifications of SM1212E433

Frequency
433MHz
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
SX1212E
If the bit synchronizer is disabled, the raw demodulator output is made directly available on DATA pin and no DCLK
signal is provided.
Conversely, if the bit synchronizer is enabled, synchronous cleaned data and clock are made available respectively
on DATA and IRQ_1 pins. DATA is sampled on the rising edge of DCLK and updated on the falling edge as
illustrated in Figure 36.
Note that in Continuous mode it is always recommended to enable the bit synchronizer to clean the DATA signal
even if the DCLK signal is not used by the uC. (bit synchronizer is automatically enabled in Buffered and Packet
mode).
The tables below give the description of the interrupts available in Continuous mode.
Table 17: Interrupt Mapping in Continuous Rx Mode
Note: In Continuous mode, no interrupt is available in Stby mode
Table 18: Interrupt Mapping in Continuous Tx Mode
Rev 2 – June 18th, 2009
ADVANCED COMMUNICATIONS & SENSING
5.3.3. Rx Processing
5.3.4. Interrupt Signals Mapping
DATA (NRZ)
DCLK
IRQ_0
Figure 36: Rx Processing in Continuous Mode
IRQ_0
IRQ_1
IRQ_1
Rx_stby_irq_0
00 (d)
01
1x
Page 42 of 77
Tx
-
DCLK
Rx
DCLK
Sync
RSSI
-
www.semtech.com
SX1212