SM1212E433 Semtech, SM1212E433 Datasheet - Page 66

no-image

SM1212E433

Manufacturer Part Number
SM1212E433
Description
RF Module For SX1212
Manufacturer
Semtech
Series
-r
Type
Transceiver, ISMr
Datasheets

Specifications of SM1212E433

Frequency
433MHz
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
SX1212E
7. Application Information
Table 34 shows the crystal resonator specification for the crystal reference oscillator circuit of the SX1212. This
specification covers the full range of operation of the SX1212 and is employed in the reference design (see section
7.5.3).
Table 34: Crystal Resonator Specification
Note that the initial frequency tolerance, temperature stability and ageing performance should be chosen in
accordance with the target operating temperature range and the receiver bandwidth selected.
The R1, P1, S1, and R2, P2, S2 dividers are configured over the SPI interface and programmed by 8 bits each, at
addresses 6 to 11. The frequency pairs may hence be switched in a single SPI cycle.
To aid the user with calculating appropriate R, P and S values, software is available to perform the frequency
calculation. The SX1212 PLL frequency Calculator Software can be downloaded from the Semtech website.
The Dynamically Linked Library (DLL) used by the software to perform these calculations is also provided, free of
charge, to users, for inclusion in automatic production testing. Key benefits of this are:
As an ultra-low power device, the SX1212 can be configured for low minimum average power consumption. To
minimize consumption the following optimized transitions between modes are shown.
Rev 2 – June 18th, 2009
ADVANCED COMMUNICATIONS & SENSING
Name
Fxtal
Cload
Rm
Co
ΔFxtal
ΔFxtal(ΔT)
ΔFxtal(Δt)
7.1. Crystal Resonator Specification
7.2. Software for Frequency Calculation
No hand trimming of the reference frequency required: the actual reference frequency of the Device Under Test
(DUT) can be easily measured (e.g. from the CLKOUT output of the SX1212) and the tool will calculate the
best frequencies to compensate for the crystal initial error.
Channel plans can be calculated and stored in the application’s memory, then adapted to the actual crystal
oscillator frequency.
7.3. Switching Times and Procedures
7.2.1. GUI
7.2.2. .dll for Automatic Production Bench
Description
Nominal frequency
Load capacitance for Fxtal
Motional resistance
Shunt capacitance
Calibration tolerance at 25+/-3°C
Stability over temperature range [-40°C ; +85°C]
Ageing tolerance in first 5 years
Page 66 of 77
Min.
13.5
-15
-20
-2
9
1
-
Typ.
12.800
15
-
-
-
-
-
Max.
16.5
100
+15
+20
15
+2
7
Unit
MHz
pF
ohms
pF
ppm
ppm
ppm/year