E54-CT1 Omron, E54-CT1 Datasheet - Page 3

TRANSFORMER CURRNT 50A E5AK/E5CK

E54-CT1

Manufacturer Part Number
E54-CT1
Description
TRANSFORMER CURRNT 50A E5AK/E5CK
Manufacturer
Omron
Datasheets

Specifications of E54-CT1

Accessory Type
Current Transformer
Input Current
50A
Transformer Mounting
Chassis
Length/height, External
25mm
Output Current
50A
Transformer Type
Current
Current Rating
50A
Mounting Type
Chassis
Supply Voltage
1000 VoltsAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
E5AK/E5CK
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
E54CT1
Z2416
J Accessories (Order Separately)
Stock Note: Shaded models are normally stocked.
Note: Refer to CompoBus/D Operation Manual (W267) and DeviceNet Catalog (P10FAX1) for details such as ratings and characteristics.
Specifications
J Ratings
Note: 1. To conform to EN50081-2 (FCC Class A) for ratings of noise terminal voltages, attach a noise filter (TDK ZCB2206-11 or equiv-
Current transformer; order
only if using heater
only if using heater
burnout alarm function
Terminal cover (supplied)
DeviceNet T-branch tap
DeviceNet shielded
connector cordsets
Terminating resistor
Supply voltage
Operating voltage range
Power consumption
Input
Input impedance
Auxiliary output
Control method
Setting method
Indication method
Control output
Remote SP input
Current transformer input
Additional functions
A--194
p
2. Fuzzy self-tuning is not provided with the E5EK-DRT.
Description
t
p
alent) to the AC power supply line.
g
d
Process Controller with DeviceNet
t
50 A load, 5.8 mm hole dia.
120 A load, 12 mm hole dia.
Provides finger protection from terminals (VDE0106 part 100)
One-branch line, with three M12 connectors
0.5 m (1.64 ft) with one female M12 connector and bare wires
1 m (3.28 ft) with one female M12 connector and bare wires
0.5 m (1.64 ft) with one male M12 connector and bare wires
1 m (3.28 ft) with one male M12 connector and bare wires
Plug model for M12 female connector, shielded; resistor rated 121 Ω
Socket model for M12 male connector, shielded resistor rated 121 Ω
Terminal block for bare wires; resistor rated 121 Ω
Current input
Voltage input
Standard
Option
100 to 240 VAC, 50/60 Hz, 24 VAC/DC
85% to 110% of rated supply voltage
15 VA (100 to 240 VAC), 12 VA (24 VAC), 8 W (24 VDC)
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, PLII
Platinum resistance thermometer: JPt100, Pt100
Current input: 4 to 20 mA, 0 to 20 mA (input impedance: 150 Ω)
Voltage input: 1 to 5 V, 0 to 5 V, 0 to 10 V (input impedance: 1 MΩ)
150 Ω
1 MΩ min.
SPST-NO, 3 A at 250 VAC (resistive load)
ON/OFF or advanced PID control (with auto-tuning)
Digital setting using front panel keys
7-segment digital display and LEDs (character height: PV: 14 mm, SV: 9.5 mm)
According to output board (see Output Board Ratings and Characteristics)
Install up to two output boards (sold separately).
Current input: 4 to 20 mA (input impedance: 150 Ω)
Connect an exclusive current transformer (E54-CT1 or E54-CT3)
Manual output, heating/cooling control, SP limiter, loop burnout alarm, SP ramp,
MV limiter, MV change rate limiter, input digital filter, input shift, run/stop, protect
functions
Run/Stop selection, etc.
E5EK- -DRT
Specifications
E54-CT1
E54-CT3
E53-COV08
DCN2-1
DCA1-5CNC5F1
DCA1-5CN01F1
DCA1-5CNC5H1
DCA1-5CN01H1
DRS2-1
DRS2-2
DRS1-T
Model