E5AR-CC43DWW-FLK AC100-240 Omron, E5AR-CC43DWW-FLK AC100-240 Datasheet
E5AR-CC43DWW-FLK AC100-240
Specifications of E5AR-CC43DWW-FLK AC100-240
E5ARCC43DWWFLKAC100240
E5AR-CC43DWW-FLK AC100-240 Summary of contents
Page 1
... Note: Be sure to read the precautions for correct use and other precautions in the following user's manual before using the Digital Controller. E5AR/E5ER Digital Controller User’s Manual (Cat. No. Z182) E5AR/E5ER Digital Controller DeviceNet Communication User’s Manual (Cat. No. H124) Refer to Safety Precautions for All E5 Models. ...
Page 2
... RS-485 (1 open, 1 close) and 1 current (transfer) output E5AR Model Serial cations E5AR-Q4B E5AR-C4B E5AR-Q43B-FLK (See note 2.) E5AR-C43B-FLK (See note 2.) E5AR-Q43DB-FLK (See note 2.) E5AR-C43DB-FLK (See note 2.) E5AR-QC43DB-FLK E5AR-Q43DW-FLK (See note 2.) E5AR-C43DW-FLK (See note 2.) E5AR-QQ43DW-FLK E5AR-CC43DWW- FLK E5AR-QQ43DWW- FLK (See note 2.) E5AR-PR4DF E5AR-PRQ43DF-FLK 2 ...
Page 3
... Can be switched between close control and floating control. Inspection Results The Inspection Report can be ordered at the same time as the Digital Controller using the following model number. Inspection Report (Sold Separately) Descriptions Inspection Report for E5AR E5AR-K Outputs (control/transfer) Auxiliary outputs (SUB) ...
Page 4
... Voltage input VDC VDC VDC (including remote SP input) (Input impedance: 150 Ω for current input, approx. 1 MΩ for voltage input) Control output Voltage (pulse) output 12 VDC max. with short-circuit protection circuit (E5AR-QQ@WW-@: 21 mA max DC DC; load: 500 Ω max. (including transfer output) Current output (Resolution: Approx. 54,000 for ...
Page 5
... I/O signal line (level communications line (level (0. MHz) (level line to line (power line, output line (relay output)) (level line to ground (power line, output line (relay output)) (level 3) 0.5 cycle, 100% (rated voltage) E5AR 5 ...
Page 6
... The values in parentheses apply when Thin Cables are used. DeviceNet power supply: 24 VDC DeviceNet power supply VDC 50 mA max. (24 VDC) 64 (includes Configurator when used) 63 CRC error detection Power supplied from DeviceNet communications connector. E5AR Drop line length Total drop line length 6 m max max max max max. ...
Page 7
... Wiring Terminals ■ E5AR Standard Controller Connections E5AR-Q4B E5AR-A4B-500 E5AR-A4B-500 24 VAC/DC 100-240 VAC Auxiliary outputs (Relay outputs SUB1 4 3 SUB2 5 Input power supply 4 COM depends on the 6 model. 5 SUB3 100 to 240 VAC 1 6 SUB4 or 24 VAC/DC 2 (no polarity E53-ARQC E5AR-A4B-500 Event inputs ...
Page 8
... OUT3 + 5 - Current output 4-20 mA DC, 500 Ω max 0-20 mA DC, 500 Ω max (Switch using output (Current) (Voltage) (Thermocouple) type setting.) (Resistance thermometer) E5AR-C43DB-FLK E5AR-A4B-500 Auxiliary outputs 100-240 VAC (Relay outputs) COM SUB1 SUB2 COM SUB3 SUB4 E53-ARCC3 B(+) 1 RS-485 OUT2 ...
Page 9
... DC, 500 Ω max 0-20 mA, DC 500 Ω max. (Current) (Voltage) (Thermocouple) (Switch using output type setting.) (Resistance thermometer) E5AR-C43DW-FLK (2-loop Control) E5AR-A4W-500 100-240 VAC E53-ARCC3 + B(+) RS-485 - A(-) OUT2 Current output + 1 4-20 mA DC, 500 Ω max. 0-20 mA DC, 500 Ω max. ...
Page 10
... E5AR-CC43DWW-FLK (4-loop Control) E5AR-A4WW-500 E5AR-A4W-500 Auxiliary outputs 24 VAC/DC 100-240 VAC B (Relay outputs COM SUB1 Input power supply depends 1 on the model SUB2 100 to 240 VAC or 24 VAC/DC (no polarity COM 4 5 SUB3 5 E53-ARCC3 6 SUB4 + 6 1 B(+) RS-485 1 - A(-) 2 OUT2 E53-ARB4 2 Current output Event inputs ...
Page 11
... E5AR DeviceNet-compatible Controller Connections E5AR-Q4B-DRT E5AR-A4B-500 E5AR-A4B-500 Auxiliary outputs 24 VAC/DC 100-240 VAC B (Relay outputs Input power supply depends 3 on the model. 3 100 to 240 VAC VAC/DC (no polarity E53-ARQC E53-ARDRT OUT2 + 2 3 DeviceNet Connector Voltage output Red (V White (CAN H) OUT1 − Voltage output ...
Page 12
... E5AR-QQ4W-DRT (2-loop Control) E5AR-A4W-500 E5AR-A4W-500 Auxiliary outputs 24 VAC/DC 100-240 VAC B (Relay outputs COM SUB1 Input power supply depends 1 on the model SUB2 100 to 240 VAC VAC/DC (no polarity) 4 COM 4 E53-ARQC 5 SUB3 SUB4 E53-ARDRT OUT2 + 2 3 Voltage output DeviceNet Connector - Red (V+) OUT1 4 White (CAN H) ...
Page 13
... Group mounting is not possible. (Maintain the specified mounting space between Controllers.) • When two or more Controllers are mounted, make sure that the surrounding temperature does not exceed the allowable operating temperature specified in the specifications. E5AR MS/NS indicators Top: MS Bottom: NS DeviceNet communications connector ...
Page 14
... Accessories (Order Separately) Terminal Cover E53-COV14 (for E5AR 28.5 10.1 Unit Label Sheet Y92S-L1 11.8 Rubber Packing Y92S-P4 (for DIN96 × 96) Order the Rubber Packing separately if it becomes lost or damaged. (Refer to page 3.) The Rubber Packing can be used to achieve an IP66 degree of protection. ...
Page 15
... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...