E5AR-CC43DWW-FLK AC100-240 Omron, E5AR-CC43DWW-FLK AC100-240 Datasheet - Page 11

no-image

E5AR-CC43DWW-FLK AC100-240

Manufacturer Part Number
E5AR-CC43DWW-FLK AC100-240
Description
CONTRLR DIGTL 100-240V 4-LOOP
Manufacturer
Omron
Series
E5ARr
Type
Digital Controllerr
Datasheet

Specifications of E5AR-CC43DWW-FLK AC100-240

Input Type
Current, Voltage, RTD, Thermocouple (Multiple)
Controller Type
On/Off
Temperature Range
Selectable, Varies By Input Type
Output Type
Current + Current
Supply Voltage
100 ~ 240VAC
Size
96mm W x 96mm H (1/4 DIN)
Features
4 Event Inputs, Second Input
Communications
RS-485 (CompoWay/F)
Display Type
LCD; 5 Digit (2), 3 Digit
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
E5AR-CC43DWW-FLKAC100-240
E5ARCC43DWWFLKAC100240
■ E5AR DeviceNet-compatible Controller Connections
E5AR-Q4B-DRT
E5AR-QC4B-DRT
OUT2
Voltage output
12 V 40 mA
OUT1
Voltage output
12 V 40 mA or
Current output
(Switch using output type setting.)
OUT2
Voltage output
12 V 40 mA
E5AR-A4B-500
Input power supply depends
on the model.
100 to 240 VAC
or 24 VAC/DC (no polarity)
E5AR-A4B-500
Input power supply depends
on the model.
100 to 240 VAC
or 24 VAC/DC (no polarity)
OUT1
Voltage output
12 V 40 mA or
Current output
(Switch using output type setting.)
E53-ARQC
E53-ARQC
4-20 mA DC, 500 Ω max.
0-20 mA DC, 500 Ω max.
4-20 mA DC, 500 Ω max.
0-20 mA DC, 500 Ω max.
24 VAC/DC
-
+
-
+
24 VAC/DC
OUT3
Current output
(Switch using output
type setting.)
E53-ARCC
OUT4
Current output
(Switch using output
type setting.)
4-20 mA DC, 500 Ω max.
0-20 mA DC, 500 Ω max.
4-20 mA DC, 500 Ω max.
0-20 mA DC, 500 Ω max.
+
-
+
-
+
-
+
-
+
-
+
-
100-240 VAC
100-240 VAC
F
F
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
A
F
A
F
-
+
+
-
G
1
2
3
4
5
6
G
G
H
H
B
B
C
C
(Current)
(Current)
I
I
+
-
+
-
E5AR-A4B-500
E5AR-A4B-500
I
I
D
D
J
J
(Voltage)
(Voltage)
-
+
(Resistance thermometer)
-
+
(Resistance thermometer)
V
V
E
K
E
K
Event inputs
Event inputs
EV1
EV2
COM
EV1
EV2
COM
PT
PT
E5AR-A4B-500
E5AR-A4B-500
E53-ARDRT
E53-ARDRT
DeviceNet Connector
DeviceNet Connector
B
(Thermocouple)
B
(Thermocouple)
1
2
3
4
5
6
1
2
3
4
5
6
Red (V+)
White (CAN H)
Blue (CAN L)
Black (V−)
Red (V+)
White (CAN H)
Blue (CAN L)
Black (V−)
-
-
+
+
TC
TC
Auxiliary outputs
(Relay outputs)
Auxiliary outputs
(Relay outputs)
(Shield)
(Shield)
1
2
3
4
5
6
K
1
2
3
4
5
6
K
COM
COM
COM
SUB1
SUB2
SUB3
SUB4
COM
SUB1
SUB2
SUB3
SUB4
E5AR-C4B-DRT
OUT2
Current output
(Switch using output
type setting.)
OUT1
Current output
(Switch using output
type setting.)
E53-ARCC
E5AR-A4B-500
Input power supply depends
on the model.
100 to 240 VAC
or 24 VAC/DC (no polarity)
4-20 mA DC, 500 Ω max.
0-20 mA DC, 500 Ω max.
4-20 mA DC, 500 Ω max.
0-20 mA DC, 500 Ω max.
-
+
24 VAC/DC
-
+
+
-
+
-
100-240 VAC
F
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
A
F
G
B
H
C
(Current)
I
E5AR-A4B-500
+
-
I
D
J
(Voltage)
-
+
(Resistance thermocouple)
V
E
K
Event inputs
EV1
EV2
COM
PT
E5AR-A4B-500
E53-ARDRT
DeviceNet Connector
B
1
2
3
4
5
6
Red (V+)
White (CAN H)
Blue (CAN L)
Black (V−)
(Thermocouple)
-
+
TC
Auxiliary outputs
(Relay outputs)
(Shield)
1
2
3
4
5
6
K
COM
SUB1
SUB2
SUB3
SUB4
COM
E5AR
11