E5AR-CC43DWW-FLK AC100-240 Omron, E5AR-CC43DWW-FLK AC100-240 Datasheet - Page 2

no-image

E5AR-CC43DWW-FLK AC100-240

Manufacturer Part Number
E5AR-CC43DWW-FLK AC100-240
Description
CONTRLR DIGTL 100-240V 4-LOOP
Manufacturer
Omron
Series
E5ARr
Type
Digital Controllerr
Datasheet

Specifications of E5AR-CC43DWW-FLK AC100-240

Input Type
Current, Voltage, RTD, Thermocouple (Multiple)
Controller Type
On/Off
Temperature Range
Selectable, Varies By Input Type
Output Type
Current + Current
Supply Voltage
100 ~ 240VAC
Size
96mm W x 96mm H (1/4 DIN)
Features
4 Event Inputs, Second Input
Communications
RS-485 (CompoWay/F)
Display Type
LCD; 5 Digit (2), 3 Digit
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
E5AR-CC43DWW-FLKAC100-240
E5ARCC43DWWFLKAC100240
Ordering Information
■ Digital Controllers
Standard Controllers
Note 1: Specify the power supply specifications when ordering. Model numbers for 100 to 240 VAC are different from those for 24 VAC/VDC.
96 × 96
mm
Size
2: These models are for 100 to 240 VAC only.
3: Can be switched between close control and floating control.
Basic control
(1 loop)
2-loop control 2-loop standard control
4-loop control 4-loop standard control
Position-pro-
portional con-
trol
(1 loop)
Control type
Single-loop standard control
Single-loop heating and cooling control
Single-loop heating and cooling control
Single-loop cascade control
Single-loop control with remote SP
Single-loop proportional control
2-loop standard control
2-loop heating and cooling control
Single-loop cascade control
Single-loop control with remote SP
Single-loop proportional control
2-loop heating and cooling control
Single-loop position-proportional control
(See note 3.)
Control mode
2 points: Pulse volt-
age and Pulse volt-
age/current
2 points: Current and
Current
2 points: Pulse volt-
age and Pulse volt-
age/current
2 points: Current and
Current
2 points: Pulse volt-
age and Pulse volt-
age/current
2 points: Current and
Current
4 points: Pulse volt-
age and Pulse volt-
age/current and
Current (2 points)
2 points: Pulse volt-
age and Pulse volt-
age/current
2 points: Current and
Current
4 points: Pulse volt-
age (2 points) and
Pulse voltage/current
(2 points)
4 points: Current out-
put (4 points)
4 points: Pulse volt-
age (2 points) and
Pulse voltage/current
(2 points)
Relay output
(1 open, 1 close)
Relay output
(1 open, 1 close) and
1 current (transfer)
output
(control/transfer)
Outputs
4
4
4
4
Auxiliary
outputs
(SUB)
Optional functions
2
6
4
4
4
inputs
Event
No
RS-485
RS-485
RS-485
No
RS-485
communi-
cations
Serial
E5AR-Q4B
E5AR-C4B
E5AR-Q43B-FLK
(See note 2.)
E5AR-C43B-FLK
(See note 2.)
E5AR-Q43DB-FLK
(See note 2.)
E5AR-C43DB-FLK
(See note 2.)
E5AR-QC43DB-FLK
E5AR-Q43DW-FLK
(See note 2.)
E5AR-C43DW-FLK
(See note 2.)
E5AR-QQ43DW-FLK
E5AR-CC43DWW-
FLK
E5AR-QQ43DWW-
FLK (See note 2.)
E5AR-PR4DF
E5AR-PRQ43DF-FLK
Model
E5AR
2