E5AR-CC43DWW-FLK AC100-240 Omron, E5AR-CC43DWW-FLK AC100-240 Datasheet - Page 14

no-image

E5AR-CC43DWW-FLK AC100-240

Manufacturer Part Number
E5AR-CC43DWW-FLK AC100-240
Description
CONTRLR DIGTL 100-240V 4-LOOP
Manufacturer
Omron
Series
E5ARr
Type
Digital Controllerr
Datasheet

Specifications of E5AR-CC43DWW-FLK AC100-240

Input Type
Current, Voltage, RTD, Thermocouple (Multiple)
Controller Type
On/Off
Temperature Range
Selectable, Varies By Input Type
Output Type
Current + Current
Supply Voltage
100 ~ 240VAC
Size
96mm W x 96mm H (1/4 DIN)
Features
4 Event Inputs, Second Input
Communications
RS-485 (CompoWay/F)
Display Type
LCD; 5 Digit (2), 3 Digit
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
E5AR-CC43DWW-FLKAC100-240
E5ARCC43DWWFLKAC100240
■ Accessories (Order Separately)
Terminal Cover
E53-COV14 (for E5AR)
Unit Label Sheet
Y92S-L1
Rubber Packing
Y92S-P4 (for DIN96 × 96)
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
28.5
10.1
95
Order the Rubber Packing separately if it becomes lost or damaged. (Refer to page 3.)
The Rubber Packing can be used to achieve an IP66 degree of protection.
(Deterioration, shrinking, or hardening of the rubber packing may occur depending on the operating environment.
Therefore, periodic replacement is recommended to ensure the level of waterproofing specified in NEMA4. The time for
periodic replacement depends on the operating environment. Be sure to confirm this point at your site. Consider one year
a rough standard. OMRON shall not be liable for the level of water resistance if the customer does not perform periodic
replacement.)
The Rubber Packing does not need to be attached if a waterproof structure is not required.
In the interest of product improvement, specifications are subject to change without notice.
95
11.8
4.8
E5AR
14