ADF4360-4BCPZ Analog Devices Inc, ADF4360-4BCPZ Datasheet - Page 18

IC INT SYNTH/VCO SEALED 24-LFCSP

ADF4360-4BCPZ

Manufacturer Part Number
ADF4360-4BCPZ
Description
IC INT SYNTH/VCO SEALED 24-LFCSP
Manufacturer
Analog Devices Inc
Type
Fanout Distribution, Integer N Synthesizer (RF)r
Datasheet

Specifications of ADF4360-4BCPZ

Pll
Yes
Input
CMOS
Output
Clock
Number Of Circuits
1
Ratio - Input:output
1:2
Differential - Input:output
No/No
Frequency - Max
1.75GHz
Divider/multiplier
Yes/No
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
24-LFCSP
Frequency-max
1.75GHz
Pll Type
Frequency Synthesis
Frequency
1.45GHz
Supply Current
10mA
Supply Voltage Range
3V To 3.6V
Digital Ic Case Style
LFCSP
No. Of Pins
24
Operating Temperature Range
0°C To +150°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
EVAL-ADF4360-4EBZ1 - BOARD EVALUATION FOR ADF4360-4
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADF4360-4BCPZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADF4360-4BCPZRL7
Manufacturer:
ELPIDA
Quantity:
147
Part Number:
ADF4360-4BCPZRL7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
ADF4360-4
CONTROL LATCH
With (C2, C1) = (0, 0), the control latch is programmed. Table 7
shows the input data format for programming the control latch.
Prescaler Value
In the ADF4360 family, P2 and P1 in the control latch set the
prescaler values.
Power-Down
DB21 (PD2) and DB20 (PD1) provide programmable power-
down modes.
In the programmed asynchronous power-down, the device
powers down immediately after latching a 1 into Bit PD1, with
the condition that PD2 has been loaded with a 0. In the pro-
grammed synchronous power-down, the device power-down is
gated by the charge pump to prevent unwanted frequency
jumps. Once the power-down is enabled by writing a 1 into
Bit PD1 (on the condition that a 1 has also been loaded to PD2),
the device goes into power-down on the second rising edge of
the R counter output, after LE goes high. When the CE pin is
low, the device is immediately disabled regardless of the state of
PD1 or PD2.
When a power-down is activated (either synchronous or
asynchronous mode), the following events occur:
• All active dc current paths are removed.
• The R, N, and timeout counters are forced to their load
• The charge pump is forced into three-state mode.
• The digital lock detect circuitry is reset.
• The RF outputs are debiased to a high impedance state.
• The reference input buffer circuitry is disabled.
• The input register remains active and capable of loading and
state conditions.
latching data.
Rev. A | Page 18 of 24
Charge Pump Currents
CPI3, CPI2, and CPI1 in the ADF4360 family determine
Current Setting 1.
CPI6, CPI5, and CPI4 determine Current Setting 2. See the
truth table in Table 7.
Output Power Level
Bits PL1 and PL2 set the output power level of the VCO. See the
truth table in Table 7.
Mute-Till-Lock Detect
DB11 of the control latch in the ADF4360 family is the mute-till-
lock detect bit. This function, when enabled, ensures that the RF
outputs are not switched on until the PLL is locked.
CP Gain
DB10 of the control latch in the ADF4360 family is the charge
pump gain bit. When it is programmed to a 1, Current Setting 2
is used. When it is programmed to a 0, Current Setting 1 is used.
Charge Pump Three-State
This bit puts the charge pump into three-state mode when
programmed to a 1. It should be set to 0 for normal operation.
Phase Detector Polarity
The PDP bit in the ADF4360 family sets the phase detector
polarity. The positive setting enabled by programming a 1 is
used when using the on-chip VCO with a passive loop filter or
with an active noninverting filter. It can also be set to 0. This is
required, if an active inverting loop filter is used.
MUXOUT Control
The on-chip multiplexer is controlled by M3, M2, and M1.
See the truth table in Table 7.
Counter Reset
DB4 is the counter reset bit for the ADF4360 family. When this
is 1, the R counter and the A, B counters are reset. For normal
operation, this bit should be 0.
Core Power Level
PC1 and PC2 set the power level in the VCO core. The recom-
mended setting is 15 mA. See the truth table in Table 7.