101-1055 Rabbit Semiconductor, 101-1055 Datasheet - Page 28

no-image

101-1055

Manufacturer Part Number
101-1055
Description
MODULE RABBIT CORE RCM3375
Manufacturer
Rabbit Semiconductor
Datasheet

Specifications of 101-1055

Module/board Type
MPU Core Module
For Use With/related Products
RCM3375
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
22
As long as you have not modified the
enter the following server address in your Web browser to bring up the Web page
served by the sample program.
Otherwise use the TCP/IP settings you entered in the
This sample program does not exhibit ideal behavior in its method of writing to the
NAND flash. However, the inefficiency attributable to the small amount of data written
in each append operation is offset somewhat by the expected relative infrequency of
these writes, and by the sample program's method of “walking” through the flash
blocks when appending data as well as when a log is cleared.
NFLASH_ERASE.c
flash chip. When the program starts running, it attempts to establish communication
with the NAND flash chip selected by the user. If the communication is successful, the
progress in erasing the blocks is displayed in the Dynamic C
blocks are erased.
Follow these instructions to set up your PC or notebook. Check with your administra-
tor if you are unable to change the settings as described here since you may need
administrator privileges. The instructions are specifically for Windows 2000, but the
interface is similar for other versions of Windows.
1. Go to the control panel (
2. Select the network interface card used for the Ethernet interface you intend to use
3. Now select the
4. Click <OK> or <Close> to exit the various dialog boxes.
http://10.10.6.100
the Network icon.
(e.g.,
ties” button. Depending on which version of Windows your PC is running, you may
have to select the “Local Area Connection” first, and then click on the “Properties”
button to bring up the Ethernet interface dialog. Then “Configure” your interface
card for a “10Base-T Half-Duplex” or an “Auto-Negotiation” connection on the
“Advanced” tab.
and click on “Properties” to assign an IP address to your computer (this will disable
“obtain an IP address automatically”):
TIP: If you are using a PC that is already on a network, you will disconnect the PC
NOTE: Your network interface card will likely have a different name.
IP Address : 10.10.6.101
Netmask : 255.255.255.0
Default gateway : 10.10.6.1
TCP/IP Xircom Credit Card Network Adapter
from that network to run these sample programs. Write down the existing settings
before changing them to facilitate restoring them when you are finished with the
sample programs and reconnect your PC to the network.
IP Address
—This program is a utility to erase all the good blocks on a NAND
Start > Settings > Control Panel
tab, and check
TCPCONFIG 1
Specify an IP Address
TCP_CONFIG.LIB
macro in the sample program,
) and click on the “Proper-
RabbitCore RCM3365/RCM3375
STDIO
), and then double-click
, or select TCP/IP
window as the
library.

Related parts for 101-1055