101-1055 Rabbit Semiconductor, 101-1055 Datasheet - Page 55

no-image

101-1055

Manufacturer Part Number
101-1055
Description
MODULE RABBIT CORE RCM3375
Manufacturer
Rabbit Semiconductor
Datasheet

Specifications of 101-1055

Module/board Type
MPU Core Module
For Use With/related Products
RCM3375
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
PARAMETERS
RETURN VALUE
SEE ALSO
5.2.6.4 Serial Communication
SEE ALSO
SEE ALSO
User’s Manual
void relayOut(int relay, int value);
void ser485Tx(void);
void ser485Rx(void);
Sets the position for the relay common contact. The default position is for normally closed contacts.
relay is the one relay (1)
value is the value used to connect the relay common contact:
None.
Enables the RS-485 transmitter. Transmitted data are echoed back into the receive data buffer. The
echoed data may be used as an indicator for disabling the transmitter by using one of the following meth-
ods:
Remember to call the serXopen() function before running this function.
Disables the RS-485 transmitter. This puts the device into the listen mode, which allows it to receive data
from the RS-485 interface.
Remember to call the serXopen() function before running this function.
Byte mode—disable the transmitter after the same byte that is transmitted is detected in the receive
Block data mode—disable the transmitter after the same number of bytes transmitted are detected in
brdInit
ser485Rx
ser485Tx
0 = normally closed positions (NC1 and NC2)
1 = normally open positions (NO1 and NO2)
data buffer.
the receive data buffer.
49

Related parts for 101-1055