AT43USB320A-AC Atmel, AT43USB320A-AC Datasheet - Page 32

IC USB MCU EMBED HUB AVR 100LQFP

AT43USB320A-AC

Manufacturer Part Number
AT43USB320A-AC
Description
IC USB MCU EMBED HUB AVR 100LQFP
Manufacturer
Atmel
Series
AVR®r
Datasheet

Specifications of AT43USB320A-AC

Applications
USB Hub/Microcontroller
Core Processor
AVR
Controller Series
AT43USB
Ram Size
512 x 8
Interface
SPI Serial, USB, UART
Number Of I /o
32
Voltage - Supply
4.4 V ~ 5.25 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
100-LQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Program Memory Type
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT43USB320A-AC
Manufacturer:
Atmel
Quantity:
10 000
USB Endpoint
Interrupt Sources
32
AT43USB320A
An assertion or activation of one or more bits in the endpoint's Control and Status Register
triggers the endpoint interrupts. These triggers are different for control and non-control end-
points as described in the table below. Please refer to the Control and Status Register for
more information.
Table 11. USB Endpoint Interrupt Sources
USB Interrupt Status Register – UISR
• Bit 7 – SOF INT: Start of Frame Interrupt
This bit is asserted after the USB hardware receives a valid SOF packet.
• Bit 6 – EOF2 INT: EOF2 Interrupt
This bit is asserted 10 clocks before the expected start of a frame.
• Bit 5, 4 – Res: Reserved Bits
These bits are reserved and always read as zero.
• Bit 3 – HEP0 INT: Hub Endpoint 0 Interrupt
• Bit 2 – FEP2 INT: Function Endpoint 2 Interrupt
• Bit 1 – FEP1 INT: Function Endpoint 1 Interrupt
• Bit 0 – FEP0 INT: Function Endpoint 0 Interrupt
The hub and function interrupt bits will be set by the hardware whenever the following bits in
the corresponding endpoint's Control and Status Register are modified by the USB hardware:
1. RX OUT Packet is set (control and OUT endpoints)
2. TX Packet Ready is cleared AND TX Complete is set (control and IN endpoints)
3. RX SETUP is set (control endpoints only)
4. TX Complete is set
Bit
RX_OUT_PACKET
TX_COMPLETE
STALL_SENT
RX_SETUP
Read/Write
Initial Value
$1FF7
Bit
SOF INT
R
7
0
EOF2 INT
6
R
0
R
5
0
R
4
0
HEP0 INT
R
3
0
Endpoint type
CONTROL, OUT
CONTROL, IN
CONTROL, IN
CONTROL
FE2 INT
R
2
0
FE1 INT
R
1
0
FE0 INT
1443E–USB–4/04
R
0
0