CXONELT01CV4 Omron Automation, CXONELT01CV4 Datasheet - Page 34

no-image

CXONELT01CV4

Manufacturer Part Number
CXONELT01CV4
Description
Support Software Development Tool
Manufacturer
Omron Automation
Type
Configuration Softwarer
Datasheet

Specifications of CXONELT01CV4

Application
Logic Control
Brand/series
CP1
Lead Free Status / Rohs Status
RoHS Compliant part
For Use With
CP1L
■ Temperature Sensor Units: CP1W-TS001/TS002/TS101/TS102
By mounting a Temperature Sensor Unit to the PLC, inputs can be obtained from thermocouples or platinum resistance thermometers, and tem-
perature measurements can be converted to binary data (4-digit hexadecimal) and stored in the input area of the CPU Unit.
● Specifications
Note: The indication accuracy when using a K-type thermocouple for temperature less than −100°C is ±4°C±1 digit max.
● Input Temperature Ranges for CP1W-TS001/002
■ CP1W-SRT21 CompoBus/S I/O Link Unit
The CompoBus/S I/O Link Unit functions as a slave for a CompoBus/S Master Unit (or an SRM1 CompoBus/S Master Control Unit) to form an I/O
Link with 8 inputs and 8 outputs between the CompoBus/S I/O Link Unit and the Master Unit.
CS/CJ Series
C200H@ Series
CQM1(H) Series
SRM1 Series
CPM2C-S Series
Item
Number of inputs
Input types
Indication accuracy
Conversion time
Converted tempera-
ture data
Isolation method
(The rotary switch can be used to make the following
range and input type settings.)
Input type
CompoBus/S Master Unit
(or SRM1 CompoBus/S
Master Control Unit)
K
J
Model
Special flat cable or VCTF cable
2 (TS001), 4 (TS002)
K, J switchable (Note: Same for all inputs.)
(The larger of the indicated value: ±0.5% and ±2°C (See note.)) ±1
digit max.
250 ms/2 points (TS001, TS101); 250 ms/4 points (TS002, TS102)
Binary (4-digit hexadecimal)
Photocoupler isolation between the temperature input signals.
−200 to 1300
−100 to 850
Range (°C)
0.0 to 500.0
0.0 to 400.0
CP1H/CP1L
CP1W-TS001/002
−300 to 2300
−100 to 1500
0.0 to 900.0
0.0 to 750.0
Range (°F)
A maximum of 16 Units can be connected
(or 8 Units for CQM1-SRM21-V1).
Expansion Unit Specifications
CP1W-SRT21
CompoBus/S I/O Link Unit
No.
COMM
ERR
BD L NC(BS-)
ON
1 2 3 4 5 6
BD H
NC(BS+)
SRT21
NC
EXP
● Input Temperature Ranges for CP1W-TS101/102
(The rotary switch can be used to make the following
range and input type settings.)
Input type
JPt100
Pt100
2 (TS101), 4 (TS102)
Pt100, JPt100 switchable (Note: Same for all inputs.)
(The larger of the indicated value: ±0.5% and ±1°C) ±1 digit max.
● Specifications
Item
Master/Slave
Number of I/O bits
Number of words
occupied in
CP1H/CP1L
I/O memory
Node number
setting
−200.0 to 650.0
−200.0 to 650.0
Range (°C)
Model
CP1W-TS101/102
CompoBus/S Slave
8 input bits, 8 output bits
1 input word, 1 output word
(Allocated in the same way as for
other Expansion Units)
Set using the DIP switch (before the
CPU Unit is turned ON.)
CP1W-SRT21
−300 to 1200.0
−300 to 1200.0
Range (°F)
47