3G3JX-A2037 Omron Automation, 3G3JX-A2037 Datasheet - Page 27

no-image

3G3JX-A2037

Manufacturer Part Number
3G3JX-A2037
Description
Drive, Adjustable Frequency, 3-Phase, 240VAC, 5.0HP, 15.9A, RS-485 Serial , IP20
Manufacturer
Omron Automation
Type
Adjustable Frequencyr
Datasheet

Specifications of 3G3JX-A2037

Brand/series
JX
Current, Input
20 A
Function
Motor Control
Horse Power Rating
5 HP
Mounting Type
Screw
Phase
Three
Power Rating
5.0 HP
Primary Type
AC Drive
Standards
IP20
Voltage, Supply
240 VAC
Voltage, Supply Maximum
240
Lead Free Status / Rohs Status
RoHS Compliant part
Protective and Diagnostic Functions
●Error Code List
*1.
*2.
*3.
*4.
*5.
*6.
Display on Digital Operator
data initialization or copying.
to release the trip.
monitor.
After a trip occurs, normal operation is restored in 10 seconds by resetting.
Check the set data again if the EEPROM error
If the power is shut off during data initialization, an EEPROM error
If an undervoltage trip
The ground fault trip
If the multi-function output (relay output) is set to 05 (alarm), the signal may not be output during the CPU error
ek k0k1
ek k0k2
ek k0k3
ek k0k4
ek k0k5
ek k0k6
ek k0k7
ek k0k8
ek k0k9
ek k1k1
ek k2k2
ek k1k2
ek k1k3
ek k1k4
ek k1k5
ek k2k1
ek k2k3
ek k3k5
ek k1k4
ek k0k9
Overcurrent trip
Overload trip
Braking resistor overload
trip
Overvoltage trip
EEPROM error
Undervoltage trip
CPU error
External trip
USP trip
Ground fault trip
Incoming overvoltage trip
Temperature error
Gate array error
Thermistor error
(Available when the
thermistor trip function is
used)
cannot be released with the reset input. Shut off the power and check the wiring.
occurs with the USP terminal set to ON, the trip, after released by resetting, becomes a USP error
*4
Name
*6
*1
*2 *3
*5
ek k0k8
Multi-functional Compact Inverters SYSDRIVE
Constant
speed
Deceleration
Acceleration
Others
If an Inverter output current is detected and the motor is overloaded, an electronic thermal inside the
Inverter works to shut off the Inverter output.
When the usage rate of the braking resistor is exceeded, this function detects overvoltage due to
operation stop of the control circuit and shuts off the Inverter output.
If the incoming voltage and regenerative energy from the motor are too high, a protection circuit works
to shut off the Inverter output when the voltage on the converter exceeds the specified level.
Shuts off the output if an error occurs in the EEPROM built into the Inverter due to external noise and
abnormal temperature rise.
Shuts off the output if the incoming voltage drops below the specified level, causing the control circuit
not to work properly during a momentary power interruption.
Shuts off the output if the internal CPU has worked erroneously or abnormally.
If an error occurs in the external equipment or devices, the Inverter receives the signal, and the output
is shut off.
(Available with the external trip function selected)
Appears if the Inverter is turned on with the RUN command being input. (Available with the USP
function selected)
Shuts off the output if a ground fault between the Inverter output unit and the motor is detected when
turning on the power.
Appears if the incoming voltage has remained high for 100 seconds while the Inverter output is
stopped.
Shuts off the output if the temperature has risen in the main circuit due to malfunction of the cooling fan
or other reason.
Displayed when a fault is detected in communication behavior between the built-in CPU and the gate
array.
Detects the resistance of the external thermistor and shuts off the Inverter output.
occurs.
ek k0k8
If the motor is restrained or rapidly accelerated or decelerated, a large current will flow
through the Inverter, which will result in breakage.
To avoid this, an overcurrent protection circuit works to shut off the Inverter output.
may occur when the power is next turned on. Shut off the power after completing
Description
ek k2k2
. In this case, no data is stored in the trip
MX
Series
ek k1k3
. Reset again
35