INT-1532-L-5-L-010 TE Connectivity, INT-1532-L-5-L-010 Datasheet - Page 29

DIGITAL PANEL METER, 4-DIGIT, 57.7V TO 139V / 100V TO 240V

INT-1532-L-5-L-010

Manufacturer Part Number
INT-1532-L-5-L-010
Description
DIGITAL PANEL METER, 4-DIGIT, 57.7V TO 139V / 100V TO 240V
Manufacturer
TE Connectivity
Datasheet

Specifications of INT-1532-L-5-L-010

No. Of Digits / Alpha
4
Meter Function
Digital
Meter Range
0mA To 20mA
Digit Height
96mm
Supply Voltage Range
57.7V To 139V / 100V To 240V
Power Consumption
3W
Rohs Compliant
NA
Measurement, Display and
Communication
Integra 1000 offers configuration,
display and communication of up to
23 electrical and power quality
parameters.
1
2
3
4
5
6
7
8
9
10 kW maximum demand
28
System volts
System current
System kW
Volts L1–N
Volts L2–N
Volts L3–N
Volts L1–L2
Volts L2–L3
Volts L3–L1
Current L1
Current L2
Current L3
Neutral current
Frequency
Power factor
kVAr
kVA
kW
kWh (7-digit resolution)
kVArh (7-digit resolution)
kW demand
Current demand
Current maximum demand
Specifications
Max short duration input voltage: 2 x for 1 second, repeated 10 times at 10
Input
Nominal input voltage:
Max continuous input voltage:
System VT ratios (primary):
Nominal input voltage burden:
Nominal input current:
System CT primary values:
Max continuous input current:
Max short duration current input:
Nominal input current burden:
Outputs
RS485 communications:
Baud rates:
Pulsed:
Pulse duration:
Auxiliary
Standard nominal supply voltage:
AC supply frequency range:
AC supply burden:
Optional auxiliary dc supply:
DC supply burden:
Measuring ranges
Voltage:
Current:
Frequency:
Power factor:
Energy:
Accuracy
Voltage:
Current:
Power:
Neutral current:
Energy:
KVArh:
Temperature coefficient:
Update time:
Enclosure
Enclosure style:
Compliant with:
Material:
Terminals:
Dielectric voltage:
Operating temperature:
Storage temperature:
Relative humidity:
Warm-up time:
Shock:
Vibration:
Enclosure
Dimensions:
Panel cut-out:
57.7 to 346V L-N, 100 to 600V L-L
120% nominal
second intervals
400kV or 360MW **
< 0.2VA
5A (1A option)
9999:5A or 9999:1A max 360MW **
120% nominal
20 x for 1 second, repeated 5 times at
5 second intervals
< 0.6VA
** maximum VT or CT ratios are limited so that
the combination of primary voltage and current
do not exceed 360MW at 120% of relevant input.
2-wire half duplex
2400, 4800, 9600, 19200
Clean contact SPNO, 100V dc 0.5A max
60, 100 or 200 milliseconds
100-250V ac or dc
(85-287V ac absolute)
(85-312V dc absolute)
45-66Hz
6VA
12-48V dc (10.2-60V dc Absolute)
6VA
50-120% of nominal (functional 5-120%)
5-120% of nominal
45-66Hz
0.5 capacitive – 1 – 0.8 inductive
7-digit resolution 360MW max
±0.1% of range ±0.4% of reading
±0.1% of range ±0.4% of reading
±0.1% of range ±0.9% of reading
±4% of range
kWh 1% IEC1036 (PF 0.8-1-0.8)
2% IEC1036 (PF 0.8-1-0.8)
0.013%/°C typical
500ms display 250ms optional digital port
ANSI C39.1
UL 140758 and IEC 1010 / BSEN 61010-1
Polycarbonate front and base, steel case
Barrier terminal strip 6-32 binding head screw
Withstand test 3.25kV rms 50Hz for
1 minute between all electrical circuits
-20 to +70°C
-30 to +80°C
0-95% (non condensing)
1 minute
30g in 3 planes
10-15Hz, 1.5mm peak-to-peak / 15-150Hz @1g
Integrity (front face only) IP54
4.31" high x 4.31" wide x 6.7" deep
109.4mm high x 109mm wide x 170.2mm deep
4.06" (103mm) diameter, 4 stud positions

Related parts for INT-1532-L-5-L-010