ADM1024ARUZ ON Semiconductor, ADM1024ARUZ Datasheet

IC MONITOR SYS TEMP/VOLT 24TSSOP

ADM1024ARUZ

Manufacturer Part Number
ADM1024ARUZ
Description
IC MONITOR SYS TEMP/VOLT 24TSSOP
Manufacturer
ON Semiconductor
Datasheet

Specifications of ADM1024ARUZ

Applications
PC's, PDA's
Interface
Serial
Voltage - Supply
2.8 V ~ 5.5 V
Package / Case
24-TSSOP
Mounting Type
Surface Mount
Temperature Sensor Function
Temp Sensor
Output Type
Digital
Package Type
TSSOP
Operating Temperature (min)
0C
Operating Temperature (max)
100C
Operating Temperature Classification
Commercial
Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (max)
5.5V
Full Temp Accuracy
+/- 2 C , +/- 3 C
Digital Output - Bus Interface
SMBus
Digital Output - Number Of Bits
10 bit
Supply Voltage (max)
12 V
Supply Voltage (min)
2.5 V
Maximum Operating Temperature
+ 100 C
Minimum Operating Temperature
0 C
Supply Current
1.4 mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADM1024ARUZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
ADM1024
System Hardware Monitor
with Remote Diode Thermal
Sensing
microprocessor−based systems, providing measurement and limit
comparison of various system parameters. Eight measurement inputs
are provided; three are dedicated to monitoring 5.0 V and 12 V power
supplies and the processor core voltage. The ADM1024 can monitor a
fourth power supply voltage by measuring its own V
(two pins) is dedicated to a remote temperature−sensing diode. Two
more pins can be configured as inputs to monitor a 2.5 V supply and a
second processor core voltage, or as a second temperature−sensing
input. The remaining two inputs can be programmed as general
purpose analog inputs or as digital fan speed measuring inputs.
Measured values can be read out via a serial System Management Bus
and values for limit comparisons can be programmed in over the same
serial bus. The high speed successive approximation ADC allows
frequent sampling of all analog channels to ensure a fast interrupt
response to any out−of−limit measurement.
current, and SMBus interface make it ideal for a wide range of
applications. These include hardware monitoring and protection
applications in personal computers, electronic test equipment, and office
electronics.
FEATURES
APPLICATIONS
© Semiconductor Components Industries, LLC, 2010
June, 2010 − Rev. 2
The ADM1024 is a complete system hardware monitor for
The ADM1024’s 2.8 V to 5.5 V supply voltage range, low supply
Inputs Programmable−to−Measure Analog Voltage,
Fan Speed or External Temperature
External Temperature Measurement with Remote Diode
(Two Channels)
Up to Nine Measurement Channels
On−Chip Temperature Sensor
Five Digital Inputs for VID Bits
LDCM Support
System Management Bus (SMBus)
Chassis Intrusion Detect
Interrupt and Overtemperature Outputs
Programmable RESET Input Pin
Shutdown Mode to Minimize Power Consumption
Limit Comparison of All Monitored Values
This is a Pb−Free Device
Network Servers and Personal Computers
Microprocessor−Based Office Equipment
Test Equipment and Measuring Instruments
CC
. One input
1
See detailed ordering and shipping information in the package
dimensions section on page 28 of this data sheet.
NTEST_OUT/ADD
NTEST_IN/AOUT
FAN1/AIN1
FAN2/AIN2
xxx
#
YYWW = Date Code
THERM
RESET
ORDERING INFORMATION
GND
SDA
V
SCL
INT
CC
MARKING DIAGRAM
CI
http://onsemi.com
1
PIN ASSIGNMENT
12
10
11
1
2
3
4
5
6
7
8
9
= Specific Device Code
= Pb−Free Package
AD1024
(Top View)
#YYWW
ARUZ
1024
Publication Order Number:
CASE 948H
TSSOP−24
24
23
22
21
20
19
18
17
16
15
14
13
VID0/IRQ0
VID1/IRQ1
VID2/IRQ2
VID3/IRQ3
VID4/IRQ4
+V
+2.5V
V
+5.0V
+12V
D1+
D1–
CCP2
CCP1
ADM1024/D
IN
IN
IN
/D2–
/D2+

Related parts for ADM1024ARUZ

ADM1024ARUZ Summary of contents

Page 1

ADM1024 System Hardware Monitor with Remote Diode Thermal Sensing The ADM1024 is a complete system hardware monitor for microprocessor−based systems, providing measurement and limit comparison of various system parameters. Eight measurement inputs are provided; three are dedicated to monitoring 5.0 ...

Page 2

V CC VID0/IRQ0 VID1/IRQ1 VID2/IRQ2 VID3/IRQ3 100k W PULLUPS VID4/IRQ4 FAN1/AIN1 FAN2/AIN2 +V CCP1 +2.5V /D2+ IN +5.0V IN +12V IN V /D2– CCP2 D1+ D1– POWER TO CHIP V CC BAND GAP TEMPERATURE SENSOR ABSOLUTE MAXIMUM RATINGS Parameter Positive ...

Page 3

PIN ASSIGNMENT Pin No. Mnemonic 1 NTEST_OUT/ADD Digital I/O. Dual function pin. This is a three−state input that controls the two LSBs of the Serial Bus Address. This pin functions as an output when doing a NAND test. 2 THERM ...

Page 4

ELECTRICAL CHARACTERISTICS Parameter POWER SUPPLY Supply Voltage Supply Current TEMPERATURE−TO−DIGITAL CONVERTER Internal Sensor Accuracy Resolution External Diode Sensor Accuracy Resolution Remote Sensor Source Current ANALOG−TO−DIGITAL CONVERTER (Including MUX and ATTENUATORS) Total Unadjusted Error (TUE) (12 V ...

Page 5

ELECTRICAL CHARACTERISTICS Parameter OPEN−DRAIN SERIAL DATABUS OUTPUT (SDA) Output Low Voltage High Level Output Leakage Current SERIAL BUS DIGITAL INPUTS (SCL, SDA) Input High Voltage Input Low Voltage Hysteresis Glitch Immunity DIGITAL ...

Page 6

TYPICAL PERFORMANCE CHARACTERISTICS DXP TO GND 0 –10 DXP –20 –30 –40 –50 –60 1 3.3 10 LEAK RESISTANCE (MΩ) Figure 3. Temperature Error vs. PC Board Track Resistance 25 20 100mV ...

Page 7

TYPICAL PERFORMANCE CHARACTERISTICS 26.5 26 3.3 V 25.5 DD 25.0 24.5 24.0 23.5 23.0 22.5 –40 – TEMPERATURE (5C) Figure 9. Standby Current vs. Temperature http://onsemi.com 7 80 100 120 ...

Page 8

General Description The ADM1024 is a complete system hardware monitor for microprocessor−based systems. The device communicates with the system via a serial SMBus. The serial bus controller has a hardwired address line for device selection (Pin 1), a serial data ...

Page 9

Value and Limit Registers: The results of analog ♦ voltage inputs, temperature, and fan speed measurements are stored in these registers, along with their limit values. Analog Output Register: The code controlling the ♦ analog output DAC is stored in ...

Page 10

A read operation is then performed consisting of the serial bus address, R/W bit set to 1, followed by the data byte read from the data register. This is shown in Figure 12 the Address Pointer Register is ...

Page 11

Bits the Channel Mode Register enable or disable Pins when they are configured as interrupt inputs by setting Bit 7 of the Channel Mode Register. This function is controlled for Pins 20 and ...

Page 12

Table 3 shows the input ranges of the analog inputs and output codes of the ADC. When the ADC is running, it samples and converts an input every 748 ms, ...

Page 13

Table 4. Theoretically, the temperature sensor and ADC can measure temperatures from −128°C to +127°C with a resolution of 1°C, although ...

Page 14

Use wide tracks to minimize inductance and reduce noise pickup mil track minimum width and spacing is recommended. GND D+ D– GND Figure 18. Arrangement of Signal Tracks 4. Try to minimize the number of copper/solder joints, ...

Page 15

Analog Output The ADM1024 has a single analog output from an unsigned 8−bit DAC that produces 2.5 V. The analog output register defaults to FF during power−on reset, which produces maximum fan speed. The analog output may ...

Page 16

In all these circuits, the output transistor must have an I greater than the maximum fan current, CMAX and be capable of dissipating power due to the voltage dropped across it when the fan is not operating at full ...

Page 17

If the fan has a strong pullup (less than 1 kW totem−pole output, then a series resistor can be added to limit the Zener current, as shown in Figure 27. Alternatively, a resistive attenuator may ...

Page 18

Table 5. Fan Speeds and Divisors Divisor RPM Nominal RPM ÷ 1 8800 ÷ 2 4400 ÷ 4 2200 ÷ 8 1100 Limit Values Fans in general will not over−speed if run from the correct voltage, so the failure condition ...

Page 19

The chassis intrusion input can also be used for other types of alarm input. Figure 31 shows a temperature alarm circuit using an AD22105 temperature switch sensor. This produces a low going output when the preset temperature is exceeded, so ...

Page 20

VID0/IRQ0 VID1/IRQ1 VID2/IRQ2 VID3/IRQ3 VID4/IRQ4 4 5 CHANNEL MODE REGISTER CONFIGURATION REGISTER 2 7 HIGH LIMIT 1 = OUT OF FROM LIMIT VALUE VALUE AND LIMIT REGISTERS LOW LIMIT MASKING DATA FROM BUS Temperature Interrupt Modes The ...

Page 21

Once the interrupt has been cleared, it will not be reasserted even if the temperature remains above the high limit(s). However, INT will be reasserted if: The temperature falls below the low limit for the sensor; or: The high limit(s) ...

Page 22

RESET Input/Output RESET (Pin 12 I/O pin that can function as an open−drain output, providing a low going 20 ms output pulse when Bit 4 of the Configuration Register is set to 1, provided the reset function has ...

Page 23

Bits 1 and 2 of Configuration Register 2 lock the values stored in the Local and Remote Fan Control Registers at addresses 13h and 14h. The values in these registers cannot be changed until a power−on reset is performed. Bit ...

Page 24

ADM Registers Table 6. Address Pointer Register Bit Name R/W 7–0 Address Pointer Table 7. List of Registers Hex Description Addr 13h Internal Temperature Hardware Trip Point 14h External Temperature Hardware Trip Point 15h Test Register 16h Channel Mode Register ...

Page 25

Hex Description Addr 35h V High Limit CCP2 36h V Low Limit CCP2 37h Ext. Temp1 High Limit 38h Ext. Temp1 Low Limit 39h Internal Temp. High Limit 3Ah Internal Temp. Low Limit 3Bh A /FAN1 High Limit IN1 3Ch ...

Page 26

Table 9. Register 40h, Configuration Register 1 (Power−On Default, 08h) Bit Name R/W 0 START R/W 1 INT_Enable R/W 2 THERM R/W Enable 3 INT_Clear R/W 4 RESET R/W 5 Reserved R/W 6 THERM CLR R/W 7 Initialization R/W Table ...

Page 27

Table 12. Register 43h, INT Interrupt Mask Register 1 (Power−On Default, 00h) Bit Name R/W 0 2.5 V/Ext. Temp2 R R/W CCP1 5.0 V R/W 4 Int. Temp R/W 5 Ext. Temp1 R/W ...

Page 28

... An error that causes continuous interrupts to be generated may be masked in its respective mask register, until the error can be alleviated. ORDERING INFORMATION Device Order Number ADM1024ARUZ ADM1024ARUZ−REEL †For information on tape and reel specifications, including part orientation and tape sizes, please refer to our Tape and Reel Packaging Specifications Brochure, BRD8011/D. *The “Z’’ suffix indicates Pb−Free part. ...

Page 29

... Opportunity/Affirmative Action Employer. This literature is subject to all applicable copyright laws and is not for resale in any manner. PUBLICATION ORDERING INFORMATION LITERATURE FULFILLMENT: Literature Distribution Center for ON Semiconductor P.O. Box 5163, Denver, Colorado 80217 USA Phone: 303−675−2175 or 800−344−3860 Toll Free USA/Canada Fax: 303− ...

Related keywords