DPX2MAA106PA106P33B0001FO ITT, DPX2MAA106PA106P33B0001FO Datasheet - Page 23

no-image

DPX2MAA106PA106P33B0001FO

Manufacturer Part Number
DPX2MAA106PA106P33B0001FO
Description
Manufacturer
ITT

Specifications of DPX2MAA106PA106P33B0001FO

Body Orientation
Straight
Gender
PIN/PIN
Termination Style
Crimp
Total Number Of Contacts
106/106POS
Number Of Contact Rows
8/8
Housing Material
Aluminum Alloy
Contact Material
Copper Alloy
Mounting Style
Panel
Contact Plating
Gold
Product Height (mm)
50.8mm
Product Length (mm)
78.99mm
Lead Free Status / Rohs Status
Not Compliant
Coaxial Cable Assembly Recommendations (Continued)
Cable Trim Dimensions
www.ittcannon.com
ARINC 404
Dimensions shown in inch (mm)
Specifications and dimensions subject to change
AB, AD, AE, AF, AG
For Code V
1. Trim cable to dimensions shown below.
3. A. Place rear insulator over dielectric and conductor into contact.
4. A. Place front insulator over contact.
For Codes AB, AD, AE, AF and AG
Setp 1 - Trim cable as shown.
Step 2 - Flare out ends of braid to permit entry of ferrule.
Step 3 - Complete termination per instructions as shown below.
a. Push ferrule under braid as far as it will go. Trim off braid extending beyond shoulder of ferrul, if
b. While holding ferrule in place pull crimp sleeve forward over braid until it is tight against shoulder on
c. Trim dielectric to the .035 (0.89)/ .030 (0.76) dimension.
d. Carefully push inner conductor through rear insulator.
e. While holding rear insulator firmly against ferrule, trim conductor to .156 (3.96)/.146 (3.71)
f.
g. Place front insulator over contact and then push assembly into coaxial shell.
h. Place parts in jaw of crimp tool. Locate jaws at start of chamfer on crimp sleeve. Press
A. Push ferrule under braid as far as it will go and press braid down tightly around ferrule.
B. Solder ends of braid to ferrule by applying a small amount of solder. Avoid excess solder as it would
C. Remove any solder exceeding the .349 (8.86) max. diameter.
D. Check the .075 (1.90) max. dielectric extension, retrim if necessary.
B. Solder contact to conductor through access hole.
C. Remove excess solder from outside of contact.
B. Push parts into coaxial shell.
C. While holding parts firmly against stop shoulder in coaxial shell, place jaw of crimp tool at back end
B, C, D & P
necessary.
ferrule. Push firmly against face of ferrule to make sure it is up tight.
dimension.
Place contact over conductor and solder.
Sleeve firmly into coaxial shell and crimp. Use Daniels crimp tool HX4-210.
AA, AC
cause braid to swell up.
of shell and crimp, use Buchanan crimp tool #612991 [.343 (8.71) across hex].
Letter
Code
H & R
G
A
E
F
K
L
S
U
V
T
J
.420/.400
.420/.400
.420/.400
.785/.745
.490/.470
.581/.561
.326/.306
.410/.390
.385/.365
.678/.658
.940/.920
.550/.540
.598/.578
A
.432/.415
.460/.440
.480/.460
.275/.255
.275/.255
.345/.325
.250/.230
.290/.270
.244/.224
.275/.255
.760/.740
.415/.405
.300/.280
Inches
B
.330/.310
.330/.310
.330/.310
.228/.208
.156/.136
.156/.136
.088/.068
.088/.068
.074/.064
.156/.136
.080/.060
.250/.240
.228/.208
See page 60 for dimensions
See page 60 for dimensions
C
.10.67/10.16
10.67/10.16
10.67/10.16
19.94/18.92
14.76/14.25
17.22/16.71
23.88/23.37
13.97/13.72
15.19/14.68
12.45/11.94
10.41/9.91
8.28/7.77
9.78/9.27
A
65
19.30/18.80
10.54/10.29
11.05/10.54
11.68/11.18
12.19/11.68
Millimeters
6.98/6.48
6.98/6.48
8.76/8.26
6.35/5.84
7.37/6.86
6.20/5.69
6.98/6.48
7.62/7.11
B
8.38/7.87
8.38/7.87
8.38/7.87
5.79/5.28
3.96/3.45
3.96/3.45
2.24/1.73
2.24/1.73
1.88/1.63
3.96/3.45
2.03/1.52
6.35/6.10
5.79/5.28
C
.350 APPROX
(8.89)
SOLDER ALL AROUND
DPX*MA Crimp
.260 (6.60)
.250 (6.35)
.349 DIA. MAX
(8.86)
CRIMP AREA
Crimp Sleeve
JACKET
B
.400 APPROX.
A
BRAID
(10.16)
.610 (15.49)
.590 (14.99)
.035 (0.89)
.030 (0.76)
FERRULE
DIELECTRIC
.156 (3.96)
.146 (3.71)
0.75 MAX.
FERRULE
REAR INSULATOR
(1.90)
INNER CONDUCTOR
CONTACT
FRONT INSULATOR
COAXIAL SHELL
C
FRONT INSULATOR

Related parts for DPX2MAA106PA106P33B0001FO