IS42S16320B-7BLI ISSI, Integrated Silicon Solution Inc, IS42S16320B-7BLI Datasheet - Page 47

no-image

IS42S16320B-7BLI

Manufacturer Part Number
IS42S16320B-7BLI
Description
DRAM 512M (32Mx16) 143MHz Industrial Temp
Manufacturer
ISSI, Integrated Silicon Solution Inc
Datasheet

Specifications of IS42S16320B-7BLI

Data Bus Width
16 bit
Package / Case
WBGA-54
Memory Size
512 Mbit
Maximum Clock Frequency
143 MHz
Access Time
6.5 ns, 5.4 ns
Supply Voltage (max)
3.6 V
Supply Voltage (min)
3 V
Maximum Operating Current
130 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IS42S16320B-7BLI
Manufacturer:
ISSI
Quantity:
603
Part Number:
IS42S16320B-7BLI
Manufacturer:
ISSI
Quantity:
20 000
IS42S86400B, IS42S16320B
PRECHARGE
The PRECHARGE command (see figure) is used to deac-
tivate the open row in a particular bank or the open row in
all banks.The bank(s) will be available for a subsequent row
access some specified time (t
command is issued. Input A10 determines whether one or
all banks are to be precharged, and in the case where only
one bank is to be precharged, inputs BA0, BA1 select the
bank. When all banks are to be precharged, inputs BA0,
BA1 are treated as “Don’t Care.” Once a bank has been
precharged, it is in the idle state and must be activated
prior to any READ or WRITE commands being issued to
that bank.
POWER-DOWN
Power-down occurs if CKE is registered LOW coincident
with a NOP or COMMAND INHIBIT when no accesses
are in progress. If power-down occurs when all banks are
idle, this mode is referred to as precharge power-down;
if power-down occurs when there is a row active in either
bank, this mode is referred to as active power-down.
Entering power-down deactivates the input and output
buffers, excluding CKE, for maximum power savings while
in standby. The device may not remain in the power-down
state longer than the refresh period (64ms) since no refresh
operations are performed in this mode.
The power-down state is exited by registering a NOP or
COMMAND INHIBIT and CKE HIGH at the desired clock
edge (meeting t
POWER-DOWN
Integrated Silicon Solution, Inc. — www.issi.com
Rev. 00F
08/11/08
cks
COMMAND
). See figure "Power-Down".
CKE
CLK
All banks idle
Enter power-down mode
rp
) after the PRECHARGE
t
NOP
CKS
Input buffers gated off
less than 64ms
PRECHARGE Command
Exit power-down mode
A0-A9, A11, A12
BA0, BA1
CKE
RAS
CAS
CLK
A10
WE
≥ t
CS
CKS
NOP
HIGH
DON'T CARE
ACTIVE
BANK ADDRESS
BANK SELECT
ALL BANKS
t
t
t
RCD
RAS
RC