V23816-N1018-L312 Infineon Technologies, V23816-N1018-L312 Datasheet - Page 9

no-image

V23816-N1018-L312

Manufacturer Part Number
V23816-N1018-L312
Description
TRANSPONDER LVDS PARALLEL 2.5GBD
Manufacturer
Infineon Technologies
Series
-r
Datasheet

Specifications of V23816-N1018-L312

Data Rate
2.5Gbps
Wavelength
1310nm
Applications
Ethernet
Voltage - Supply
3.13 V ~ 3.46 V
Connector Type
LC
Mounting Type
Chassis Mount
Lead Free Status / Rohs Status
Contains lead / RoHS non-compliant
Other names
V23816-N1018IN
5. The receiver lock range is typically 300 ppm from nominal OC-48
6. RX_MON ouput voltage is measured between V CC (+) and
Connector Pin Assignments
Fiber Optics
Pin #
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
43
45
47
49
51
53
55
57
59
BLADE GND
output to switch HIGH (ON). Hysteresis occurs when the optical
input power is raised back above the threshold switching level. The
RX_LOSYNC output is an active high LVTTL output, which is set
HIGH if the Clock Data Recovery PLL becomes unlocked. Loss Of
Sync will occur at a lower optical input power level than LOS, but still
within the specified input power range.
data rate. When the data rate of the RX signal deviates by more than
(LOS) condition, then the Clock Recovery module will lock to an
internal 155.52 MHz crystal oscillator. Under this condition: The
appropriate fault output (RX_LOS or RX_LOSYNC) switches active;
The RXDATAP/N[3:0] output data is forced to all zeros; and, the
switching of the SDSCLKP/N output is done so that the clock is con-
tinuous, and there are no violations of the minimum pulse width and
period.
RX_MON (–). RX_MON is specified up to a maximum optical input
average power of –5 dBm (316.2 µW).
600 ppm (typically) from nominal, or if the RX is in a Loss Of Signal
Signal Name
TXDATAP0
TXDATAN0
GND
TXDATAP1
TXDATAN1
GND
TXDATAP2
TXDATAN2
GND
TXDATAP3
TXDATAN3
GND
TXCLKN
TXCLKP
GND
REFCLKP
REFCLKN
GND
PHASE_INITP
PHASE_INITN
VCC
PHASE_ERRN
PHASE_ERRP
VCC
LASER_DISABLE
TXLOCK
TX_FAULT
RX_LOS
RX_LOSYNC
TX_BIASMON
Pin #
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
50
52
54
56
58
60
Signal Name
SLPTIME
RLPTIME
GND
PCLKN
PCLKP
GND
SDSCLKP
SDSCLKN
GND
RXDATAN3
RXDATAP3
GND
RXDATAN2
RXDATAP2
GND
RXDATAN1
RXDATAP1
GND
LLEB_L
DLEB_L
RXDATAN0
RXDATAP0
VCC
VCC
VCC
VCC
VCC
RESET_L
RX_MON
SPARE
V23816-N1018-C/L312, 3.3V, 4-Line LVDS Parallel 2.5GBd Transp.OC-48 SONET/SDH SR, 2km
9
Agency Certifications
Typical RX_MON Characteristic (Linear)
Typical RX_MON Characteristic (Logarithmic)
Feature
Electrostatic Dis-
charge (ESD) to
the Electrical Pins
Immunity:
Electrostatic
Discharge (ESD)
to Housing/Pigtails
Immunity:
Radio Frequency
Electromagnetic
Field
Emission:
Electromagnetic
Interference (EMI)
1,6
1,4
1,2
1
0,8
0,6
0,4
0,2
0
1,6
1,4
1,2
1
0,8
0,6
0,4
0,2
0
-25
0
-20
Standard
EIA/JESD22-A114-A
(MIL-STD 883D
Method 3015.7)
EN 61000-4-2
IEC 61000-4-2
EN 61000-4-3
IEC 61000-4-3
FCC Part 15, Class B
EN 55022 Class B
CISPR 22
RX Input Average Power (mW)
RX Input Average Power (dBm)
0,1
-15
0,2
Comments
Class 1 (2000 V)
Discharges ranging
from 2 kV to 15 kV
on housing/pigtails
cause no damage to
transponder (under
recommended condi-
tions).
With a field strength of
10 V/m rms, noise
frequency ranges from
10 MHz to 2 GHz. No
effect on transponder
performance between
the specification limits.
Noise frequency range:
250 MHz to 18 GHz
-10
0,3
-5