ISP1160BD/01,151 NXP Semiconductors, ISP1160BD/01,151 Datasheet - Page 57

ISP1160BD/01,151

Manufacturer Part Number
ISP1160BD/01,151
Description
Manufacturer
NXP Semiconductors
Datasheet

Specifications of ISP1160BD/01,151

Operating Temperature (max)
85C
Operating Temperature (min)
-40C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Lead Free Status / Rohs Status
Compliant
Philips Semiconductors
9397 750 13963
Product data
Table 35:
Bit
2
1
0
HcRshPortStatus[1:2] register: bit description
Symbol
PSS
PES
CCS
Rev. 05 — 24 December 2004
Description
On read—PortSuspendStatus: This bit indicates whether the port
is suspended or in the resume sequence. It is set by a
SetSuspendState write and cleared when
PortSuspendStatusChange is set at the end of the resume
interval. This bit cannot be set if CurrentConnectStatus is cleared.
This bit is also cleared when PortResetStatusChange is set at the
end of the port reset or when the HC is placed in the USBResume
state. If an upstream resume is in progress, it should propagate to
the HC.
0 — port is not suspended
1 — port is suspended
On write—SetPortSuspend: The HCD sets
bit PortSuspendStatus by writing a logic 1 to this bit. Writing a
logic 0 has no effect. If CurrentConnectStatus is cleared, this write
does not set PortSuspendStatus; instead it sets
ConnectStatusChange. This informs the driver that it attempted to
suspend a disconnected port.
On read—PortEnableStatus: This bit indicates whether the port is
enabled or disabled. The Root Hub may clear this bit when an
overcurrent condition, disconnect event, switched-off power, or
operational bus error such as babble is detected. This change also
causes PortEnabledStatusChange to be set. The HCD sets this bit
by writing SetPortEnable and clears it by writing ClearPortEnable.
This bit cannot be set when CurrentConnectStatus is cleared. This
bit is also set at the completion of a port reset when
ResetStatusChange is set or port is suspended when
SuspendStatusChange is set.
0 — port is disabled
1 — port is enabled
On write—SetPortEnable: The HCD sets PortEnableStatus by
writing a logic 1. Writing a logic 0 has no effect. If
CurrentConnectStatus is cleared, this write does not set
PortEnableStatus, but instead sets ConnectStatusChange. This
informs the driver that it attempted to enable a disconnected port.
On read—CurrentConnectStatus: This bit reflects the current
state of the downstream port.
0 — no device connected
1 — device connected
On write—ClearPortEnable: The HCD writes a logic 1 to this bit to
clear bit PortEnableStatus. Writing a logic 0 has no effect.
CurrentConnectStatus is not affected by any write.
Remark: This bit always reads logic 1 when the attached device is
nonremovable (DeviceRemoveable[NDP]).
Embedded USB Host Controller
© Koninklijke Philips Electronics N.V. 2004. All rights reserved.
…continued
ISP1160
56 of 88

Related parts for ISP1160BD/01,151