AD7621 Analog Devices, AD7621 Datasheet - Page 21

no-image

AD7621

Manufacturer Part Number
AD7621
Description
16-Bit, 2 LSB INL, 3 MSPS PulSAR® ADC
Manufacturer
Analog Devices
Datasheet

Specifications of AD7621

Resolution (bits)
16bit
# Chan
1
Sample Rate
3MSPS
Interface
Byte,Par,Ser,SPI
Analog Input Type
Diff-Uni
Ain Range
(2Vref) p-p
Adc Architecture
SAR
Pkg Type
CSP,QFP

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7621ACPZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7621AST
Manufacturer:
AD
Quantity:
2
Part Number:
AD7621AST
Manufacturer:
ADI
Quantity:
260
Part Number:
AD7621ASTZ
Manufacturer:
Analog Devices Inc
Quantity:
10 000
Part Number:
AD7621ASTZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7621ASTZRL
Manufacturer:
Analog Devices Inc
Quantity:
10 000
INTERFACES
DIGITAL INTERFACE
The AD7621 has a versatile digital interface that can be set up
as either a serial or parallel interface with the host system. The
serial interface is multiplexed on the parallel data bus. The
AD7621 digital interface also accommodates 2.5 V, 3.3 V, or 5 V
logic with either OVDD at 2.5 V or 3.3 V. OVDD defines the
logic high output voltage. In most applications, the OVDD
supply pin of the AD7621 is connected to the host system
interface 2.5 V or 3.3 V digital supply. Finally, by using the
OB/ 2C input pin, both twos complement or straight binary
coding can be used.
The two signals, CS and RD , control the interface. When at least
one of these signals is high, the interface outputs are in high
impedance. Usually, CS allows the selection of each AD7621 in
multicircuit applications and is held low in a single AD7621
design. RD is generally used to enable the conversion result on
the data bus.
RESET
The RESET input is used to reset the AD7621 and generate a
fast initialization. A rising edge on RESET aborts the current
conversion (if any) and tristates the data bus. The falling edge of
RESET clears the data bus and engages the initialization process
indicated by pulsing BUSY high. Conversions can take place
after the falling edge of BUSY. Refer to Figure 32 for the RESET
timing details.
RESET
CNVST
DATA
BUSY
t
9
t
38
Figure 32. RESET Timing
t
39
t
8
Rev. 0 | Page 21 of 32
PARALLEL INTERFACE
The AD7621 is configured to use the parallel interface when
SER/ PAR is held low.
Master Parallel Interface
Data can be continuously read by tying CS and RD low thus
requiring minimal microprocessor connections. However, in
this mode the data bus is always driven and cannot be used in
shared bus applications (unless the device is held in RESET).
Figure 33 details the timing for this mode.
Slave Parallel Interface
In slave parallel reading mode, the data can be read either after
each conversion, which is during the next acquisition phase, or
during the following conversion, as shown in Figure 34 and
Figure 35, respectively. When the data is read during the
conversion, it is recommended that it is read-only during the
first half of the conversion phase. This avoids any potential
feedthrough between voltage transients on the digital interface
and the most critical analog conversion circuitry.
CS = RD = 0
CNVST
BUSY
DATA
BUSY
DATA
BUS
BUS
Figure 33. Master Parallel Data Timing for Reading (Continuous Read)
Figure 34. Slave Parallel Data Timing for Reading (Read After Convert)
CS
RD
t
3
t
12
PREVIOUS CONVERSION DATA
t
CONVERSION
1
CURRENT
t
13
t
10
t
4
t
11
AD7621
NEW DATA

Related parts for AD7621