Specifications of BTS 4300SGA

Packages
PG-DSO-8
Channels
1.0
Ron @ Tj = 25°c
300.0 mOhm
Recommended Operating Voltage Min.
5.0 V
Recommended Operating Voltage Max.
34.0 V
Il(sc)
4.0 A
7
For diagnosis purpose, the BTS4300SGA provides a status pin.
7.1
BTS4300SGA status pin is an open drain, active low circuit.
no “hard” failure mode occurs (Short circuit to GND / Over temperature or open load in OFF), the signal is
permanently high, and due to a required external pull-up to the logic voltage will exhibit a logic high in the
application. A suggested value for the R
.
Figure 11
7.2
Table 3
Table 3
Device operation
Normal operation
Open Load channel
Over temp channel
Short circuit to GND
1)
7.2.1
For open load diagnosis in OFF-state, an external output pull-up resistor (
of the pull-up resistor value, the leakage currents and the open load threshold voltage
account.
I
leakages e.g due to humidity, corrosion, etc... in the application.
Data Sheet
leakage
V
ouT
defines the leakage current in the complete system, including
< 2V typ.
gives a quick reference for the logical state of the ST pin during device operation.
Figure 12
Diagnostic Mechanism
ST Pin
Status output circuitry
ST Signal in Case of Failures
ST pin truth table
Diagnostic in Open Load, Channel OFF
gives a sketch of the situation and
Channel 0
Diagnostic
Logic
PU ST
is 15k
GND
Figure 13
IN
L
H
L
H
L
H
L
H
17
ZD
ST
ESD
Figure 11
ST pin full diag.vsd
shows the typical timing diagram.
R
PU ST
shows the equivalent circuitry. As long as
V
I
ccµC
L(OFF)
R
OUT
L
H
H
H
L
L
L
L
1)
OL
R
) is recommended. For calculation
ST
(see
V
Chapter
OL(OFF)
Diagnostic Mechanism
Rev. 1.0, 2008-03-18
has to be taken into
ST
H
H
L
H
H
L
H
L
5.4) and external
BTS4300SGA

Related parts for BTS 4300SGA