HT0610 Holtek Semiconductor Inc., HT0610 Datasheet - Page 18

no-image

HT0610

Manufacturer Part Number
HT0610
Description
Ht0610 -- 33x120 Lcd Driver
Manufacturer
Holtek Semiconductor Inc.
Datasheet
Command Required for Display Mode Setup
Other related command with display mode: set duty cycle, set column mapping, set row mapping, set vertical scroll
value.
Command Related to Internal DC/DC Converter
Set oscillator disable/enable, set internal regulator on/off, set duty cycle, set temperature coefficient, set internal con-
trast control on/off, increase contrast level, set internal voltage divider on/off, set bias ratio, set display on/off, set inter-
nal/external oscillator, set contrast level, set voltage doubler/tripler, set 33 mux display mode, set Icon display mode.
* You do not need to resend the command again if it is set previously.
Command Required for R/W Actions on RAM
* You do not need to resend the command again if it is set previously.
Rev. 1.10
Display Mode
Static Icon Display
Standby Mode 1
Standby Mode 2
Standby Mode 3
Read data from BGDRAM
Write data to BGDRAM
Save or restore BGDRAM column address
Increase BGDRAM address by one
Master clear BGDRAM
Display Mode
R/W Actions on RAM
Set external/internal oscillator*
Set oscillator enable*
Set display on*
Set external/internal oscillator*
Set oscillator enable*
Set static Icon control signal*
Set display off*
Set oscillator disable*
Set external oscillator*
Set static Icon control signal*
Set display off*
Set oscillator enable*
Set internal oscillator*
Set static Icon control signal*
Set display off*
Set oscillator enable*
18
Set BGDRAM page address*
Set BGDRAM column address*
Read/write data
Save or restore BGDRAM column address
Dummy read data
Master clear BGDRAM
Dummy write data
Command Required
Command Required
April 4, 2007
HT0610

Related parts for HT0610