TSOP4833ZC1 Vishay Telefunken, TSOP4833ZC1 Datasheet - Page 3

no-image

TSOP4833ZC1

Manufacturer Part Number
TSOP4833ZC1
Description
Photo Modules for PCM Remote Control Systems
Manufacturer
Vishay Telefunken
Datasheet
Suitable Data Format
The circuit of the TSOP48..ZC1 is designed in that way
that unexpected output pulses due to noise or
disturbance signals are avoided. A bandpassfilter, an
integrator stage and an automatic gain control are
used to suppress such disturbances.
The distinguishing mark between data signal and
disturbance signal are carrier frequency, burst length
and duty cycle.
The data signal should fullfill the following condition:
frequency of the bandpass (e.g. 38kHz).
cycles a gap time of at least 14 cycles is necessary.
corresponding gap time is necessary at some time in
the data stream. This gap time should be at least 4
times longer than the burst.
continuously.
Document Number 82132
Rev. 3, 29-Mar-01
Carrier frequency should be close to center
Burst length should be 10 cycles/burst or longer.
After each burst which is between 10 cycles and 70
For each burst which is longer than 1.8ms a
Up to 800 short bursts per second can be received
0
0
Figure B: IR Signal from Fluorescent Lamp with high Modulation
Figure A: IR Signal from Fluorescent Lamp with low Modulation
5
5
time [ms]
time [s]
10
10
Some examples for suitable data format are:
NEC Code, Toshiba Micom Format, Sharp Code, RC5
Code, RC6 Code, R–2000 Code.
When a disturbance signal is applied to the
TSOP48..ZC1 it can still receive the data signal.
However the sensitivity is reduced to that level that no
unexpected pulses will occure.
Some examples for such disturbance signals which
are suppressed by the TSOP48..ZC1 are:
frequency
ballast with high or low modulation (see Figure A or
Figure B).
DC light (e.g. from tungsten bulb or sunlight)
Continuous signal at 38kHz or at any other
Signals from fluorescent lamps with electronic
15
15
Vishay Telefunken
TSOP48..ZC1
www.vishay.com
20
20
3 (7)