LM3S8933 Luminary Micro, Inc, LM3S8933 Datasheet - Page 429

no-image

LM3S8933

Manufacturer Part Number
LM3S8933
Description
Lm3s8933 Arm Microcontroller
Manufacturer
Luminary Micro, Inc
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM3S8933
Manufacturer:
DSP
Quantity:
852
Part Number:
LM3S8933-EQC50-A2
Manufacturer:
Texas Instruments
Quantity:
10 000
Part Number:
LM3S8933-EQC50-A2T
Manufacturer:
Texas Instruments
Quantity:
10 000
Part Number:
LM3S8933-IBZ50-A2
Manufacturer:
STM
Quantity:
3 002
Part Number:
LM3S8933-IBZ50-A2
Manufacturer:
Texas Instruments
Quantity:
10 000
Part Number:
LM3S8933-IBZ50-A2T
Manufacturer:
Texas Instruments
Quantity:
10 000
Part Number:
LM3S8933-IQC50-A2
Manufacturer:
TI
Quantity:
120
Part Number:
LM3S8933-IQC50-A2
Manufacturer:
Texas Instruments
Quantity:
10 000
Reset
Reset
Type
Type
CAN Control (CANCTL)
CAN0 base: 0x4004.0000
Offset 0x000
Type R/W, reset 0x0000.0001
July 25, 2008
Bit/Field
31:8
7
6
5
4
3
RO
RO
31
15
0
0
Register 1: CAN Control (CANCTL), offset 0x000
This control register initializes the module and enables test mode and interrupts.
The bus-off recovery sequence (see CAN Specification Rev. 2.0) cannot be shortened by setting
or resetting INIT. If the device goes bus-off, it sets INIT, stopping all bus activities. Once INIT
has been cleared by the CPU, the device then waits for 129 occurrences of Bus Idle (129 * 11
consecutive High bits) before resuming normal operations. At the end of the bus-off recovery
sequence, the Error Management Counters are reset.
During the waiting time after INIT is reset, each time a sequence of 11 High bits has been monitored,
a Bit0Error code is written to the CANSTS status register, enabling the CPU to readily check
whether the CAN bus is stuck Low or continuously disturbed, and to monitor the proceeding of the
bus-off recovery sequence.
RO
RO
30
14
0
0
reserved
reserved
RO
RO
29
13
0
0
Name
CCE
DAR
Test
EIE
RO
RO
28
12
0
0
reserved
RO
RO
27
11
0
0
Type
R/W
R/W
R/W
R/W
RO
RO
RO
RO
26
10
0
0
0x0000
Reset
RO
RO
25
0
9
0
0
0
0
0
0
Preliminary
RO
RO
24
0
8
0
Description
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
Test Mode Enable
0: Normal Operation
1: Test Mode
Configuration Change Enable
0: Do not allow write access to the CANBIT register.
1: Allow write access to the CANBIT register if the INIT bit is 1.
Disable Automatic Retransmission
0: Auto retransmission of disturbed messages is enabled.
1: Auto retransmission is disabled.
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
Error Interrupt Enable
0: Disabled. No Error Status interrupt is generated.
1: Enabled. A change in the Boff or EWarn bits in the CANSTS register
generates an interrupt.
reserved
R/W
Test
RO
23
0
7
0
CCE
R/W
RO
22
0
6
0
DAR
R/W
RO
21
0
5
0
reserved
RO
RO
20
0
4
0
LM3S8933 Microcontroller
R/W
EIE
RO
19
0
3
0
R/W
RO
SIE
18
0
2
0
R/W
RO
17
IE
0
1
0
INIT
R/W
RO
16
0
0
1
429

Related parts for LM3S8933