wm8903 Wolfson Microelectronics plc, wm8903 Datasheet - Page 68
wm8903
Manufacturer Part Number
wm8903
Description
Ultra Low Power Codec For Portable Audio Applications
Manufacturer
Wolfson Microelectronics plc
Datasheet
1.WM8903.pdf
(158 pages)
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
wm8903LGEFK
Manufacturer:
MICRO
Quantity:
10 948
Part Number:
wm8903LGEFK
Manufacturer:
WOLFSON
Quantity:
20 000
Company:
Part Number:
wm8903LGEFK/RV
Manufacturer:
SHARP
Quantity:
93
Part Number:
wm8903LGEFK/RV
Manufacturer:
WOFLSON
Quantity:
20 000
Company:
Part Number:
wm8903LGEFK/RVA
Manufacturer:
SHARP
Quantity:
709
Part Number:
wm8903LGEFK/RVA
Manufacturer:
WOFLSON
Quantity:
20 000
WM8903
w
A pop-suppressed start-up requires VMID to be enabled smoothly, without the step change normally
associated with the initial stage of the VMID capacitor charging. A pop-suppressed start-up also
requires the analogue bias current to be enabled throughout the signal path prior to the VMID
reference voltage being applied. The WM8903 incorporates pop-suppression circuits which address
these requirements.
The alternate current source (Start-Up Bias) is enabled by STARTUP_BIAS_ENA. The start-up bias
is selected (in place of the normal bias) by POBCTRL. It is recommended that the start-up bias is
used during start-up, before switching back to the higher quality, normal bias.
VMID_IO_ENA has the same functionality as STARTUP_BIAS_ENA. The start-up bias is enabled by
setting either of these bits.
A soft-start circuit is provided in order to control the switch-on of the VMID reference. The soft-start
control circuit is enabled by setting VMID_SOFT. Three slew rates are provided, under control of the
VMID_SOFT field. When the soft-start circuit is enabled prior to enabling VMID_RES, the reference
voltage rises smoothly, without the step change that would otherwise occur. It is recommended that
the soft-start circuit and the output signal path be enabled before VMID is enabled by VMID_RES.
A soft shut-down is provided, using the soft-start control circuit and the start-up bias current
generator. The soft shut-down of VMID is achieved by setting VMID_SOFT, STARTUP_BIAS_ENA
and POBCTRL to select the start-up bias current and soft-start circuit prior to setting VMID_RES=00.
Table 44 Soft Start Control
R4 (04h)
Bias Control
0
R5 (05h)
VMID
Control 0
REGISTER
ADDRESS
4:3
BIT
4
1
5
POBCTRL
STARTUP_BIAS_
ENA
VMID_IO_ENA
VMID_SOFT [1:0]
LABEL
DEFAULT
10
1
0
0
Selects the bias current source
0 = Normal bias
1 = Start-Up bias
Enables the Start-Up bias current
generator
0 = Disabled
1 = Enabled
Enables the Start-Up bias current
generator
0 = Disabled
1 = Enabled
(same functionality as
STARTUP_BIAS_ENA)
VMID soft start enable / slew rate
control
00 = Disabled
01 = Fast soft start
10 = Nominal soft start
11 = Slow soft start