adum1100 Analog Devices, Inc., adum1100 Datasheet - Page 9

no-image

adum1100

Manufacturer Part Number
adum1100
Description
Icoupler Digital Isolator
Manufacturer
Analog Devices, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
adum1100AR
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
adum1100AR-RL7
Manufacturer:
STM
Quantity:
3 706
Part Number:
adum1100ARZ
Manufacturer:
ADI
Quantity:
5 000
Part Number:
adum1100ARZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Company:
Part Number:
adum1100ARZ
Quantity:
10 000
Part Number:
adum1100ARZ-RL7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
adum1100BR
Manufacturer:
TI
Quantity:
8
Part Number:
adum1100BR
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
adum1100BR-RL7
Manufacturer:
TI
Quantity:
6 053
Part Number:
adum1100BRZ-RL7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
PACKAGE CHARACTERISTICS
Table 4.
Parameter
Resistance (Input-to-Output)
Capacitance (Input-to-Output)
Input Capacitance
IC Junction-to-Case Thermal Resistance, Side 1
IC Junction-to-Case Thermal Resistance, Side 2
Package Power Dissipation
1
2
REGULATORY INFORMATION
The ADuM1100 is approved by the following organizations.
Table 5.
UL
Recognized under 1577
component recognition program
Single/basic insulation,
2500 V rms isolation voltage
File E214100
1
2
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 6.
Parameter
Minimum External Air Gap (Clearance)
Minimum External Tracking (Creepage)
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Isolation Group
Maximum Working Voltage Compatible with 50 Years
The device is considered a 2-terminal device; Pin 1, Pin 2, Pin 3, and Pin 4 are shorted together, and Pin 5, Pin 6, Pin 7, and Pin 8 are shorted together.
Input capacitance is measured at Pin 2 (V
In accordance with UL 1577, each ADuM1100 is proof tested by applying an insulation test voltage ≥3000 V rms for 1 sec (current leakage detection limit = 5 μA).
In accordance with DIN V VDE V 0884-10, each ADuM1100 is proof tested by applying an insulation test voltage ≥1050 V peak for 1 sec (partial discharge detection
limit = 5 pC). The * marking branded on the component designates DIN V VDE V 0884-10 approval.
Service Life
2
1
1
1
I
).
CSA
Approved under CSA Component
Acceptance Notice #5A
Basic insulation per CSA 60950-1-03 and IEC 60950-1,
400 V rms (565 V peak) maximum working voltage
File 205078
Symbol
R
C
C
θ
θ
P
JCI
JCO
PD
I-O
I-O
I
Symbol
L(I01)
L(I02)
CTI
V
IORM
Rev. G | Page 9 of 20
Min
Value
4.90 min
4.01 min
0.016 min
>175
IIIa
565
Typ
10
1.0
4.0
46
41
12
Max
240
Unit
mm
mm
mm
V
V peak
Unit
Ω
pF
pF
°C/W
°C/W
mW
Conditions
Measured from input terminals to output terminals,
shortest distance through air
Measured from input terminals to output terminals,
shortest distance path along body
Insulation distance through insulation
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table I)
Continuous peak voltage across the isolation barrier
Test Conditions
f = 1 MHz
Thermocouple located at
center of package underside
VDE
Certified according to DIN V VDE V
0884-10 (VDE V 0884-10):2006-12
Reinforced insulation, 560 V peak
File 2471900-4880-0001
ADuM1100
2

Related parts for adum1100