adum2400 Analog Devices, Inc., adum2400 Datasheet - Page 12

no-image

adum2400

Manufacturer Part Number
adum2400
Description
Quad-channel Digital Isolators, 5kv
Manufacturer
Analog Devices, Inc.
Datasheet
ADuM2400/ADuM2401/ADuM2402
PACKAGE CHARACTERISTICS
Table 4.
Parameter
Resistance (Input-Output)
Capacitance (Input-Output)
Input Capacitance
IC Junction-to-Case Thermal Resistance, Side 1
IC Junction-to-Case Thermal Resistance, Side 2
NOTES
1
2
REGULATORY INFORMATION (PENDING)
The ADuM240x will approved upon product release by the following organizations:
Table 5.
NOTES
1
2
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 6.
UL
Recognized under 1577
component recognition program
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
Minimum External Tracking (Creepage)
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index) CTI
Isolation Group
Device considered a two-terminal device: Pins 1, 2, 3, 4, 5, 6, 7, and 8 shorted together and Pins 9, 10, 11, 12, 13, 14, 15, and 16 shorted together.
Input capacitance is from any input data pin to ground.
In accordance with UL1577, each ADuM240x is proof tested by applying an insulation test voltage ≥ 6000 V rms for 1 second (current leakage detection limit = 5 µA).
In accordance with DIN EN 60747-5-2, each ADuM240x is proof tested by applying an insulation test voltage ≥ 1050 V peak for 1 second (partial discharge detection
limit = 5 pC).
Double insulation, 5000 V rms
isolation voltage
1
2
1
1
1
CSA
Approved under CSA Component
Acceptance Notice #5A
Approved per IEC 60601-1
Reinforced insulation per
CSA 60950-1-03 and IEC 60950-1,
400 V rms maximum working
voltage
Reinforced insulation, 250 V rms
maximum working voltage
Symbol
L(I01)
L(I02)
Symbol
R
C
C
θ
θ
I-O
I-O
I
jci
jco
Rev. PrD| Page 12 of 23
Value
5000
7.45 min.
8.10 min.
0.025 min. mm
>175
IIIa
Unit
V rms
mm
mm
V
Min
VDE
Certified according to DIN EN 60747-5-2
(VDE 0884 Part 2):2003-01
Complies with DIN EN 60747-5-2 (VDE 0884 Part 2):2003-01,
DIN EN 60950 (VDE 0805):2001-12; EN 60950:2000
1 minute duration.
Conditions
Measured from input terminals to output terminals,
shortest distance through air.
Measured from input terminals to output terminals,
shortest distance path along body.
Insulation distance through insulation.
DIN IEC 112/VDE 0303 Part 1.
Material Group (DIN VDE 0110, 1/89, Table 1).
Basic insulation, 848 V peak
Reinforced insulation, 565 V peak
Typ
10
2.2
4.0
33
28
2
12
Max
Preliminary Technical Data
Unit
pF
pF
°C/W
°C/W
2
Test Conditions
f = 1 MHz
Thermocouple located
at center of package
underside

Related parts for adum2400