3b34-03 Analog Devices, Inc., 3b34-03 Datasheet - Page 5

no-image

3b34-03

Manufacturer Part Number
3b34-03
Description
Isolated, Linearized Rtd Input
Manufacturer
Analog Devices, Inc.
Datasheet
1
2
3
4
5
6
voltage output is used, loop power is not required.
Specifications subject to change without notice
For a 0 mA to 20 mA range, a typical minimum output current is 10 µA.
Includes the combined effects of repeatability, hysteresis, and nonlinearity.
Linearization conformity error is ±0.05%.
With respect to the voltage output.
A wide range of custom zero suppression and span is available with the 3B30-00 and 3B31-00 models, using the AC1310 ranging card.
+24 V dc loop power is required for driving the current output at loads up to 850
+24 V dc Loop Supply
Mechanical Dimensions
Temperature Range
Relative Humidity, 24 hours
RFI Susceptibility
Rated Operation
Current
Sensitivity
Rated Performance
Storage
+12 V dc to +30 V dc
+27 mA @ l
±0.0002% span/V
3.15" x 3.395" x 0.775"
(80.0 mm x 86.2 mm x 19.7 mm)
-25°C to +85°C
-55°C to +85°C
0 to 95% @ +60°C noncondensing
±0.5% Span error @ 400 MHz, 5 Watt, 3 ft
Rev. 0 | Page 5 of 8
Environmental
. If a current output load of 400
out
= 20 mA
or less is applied, +15 V dc is sufficient for loop power. If only
3B34

Related parts for 3b34-03