hv110 Supertex, Inc., hv110 Datasheet

no-image

hv110

Manufacturer Part Number
hv110
Description
Power-over-ethernet Interface Pd Controller Meets Ieee802.3af Tm Standard
Manufacturer
Supertex, Inc.
Datasheet
Features
Applications
Typical Application
Supertex, Inc.
or Step Voltage at Input Supply
IP Phones
Wireless Access Points
End-Spans and Mid-Spans
PoE Routers, Switches
Chargers
Security Peripherals & Cameras
Implements IEEE802.3af Standard for PD
400mA Inrush Current Limit
350mA Operating Current
400mA Fault Current Limit
Fast Response Current Limit when Over Current
Programmable UVLO/ENABLE pin
9 seconds Auto Restart
Built in Thermal Shutdown with Hysteresis
90V Open Drain PWRGD (active low) output.
Optional Turn on Timeout Disable
On Board 90V, 1Ω MOSFET
Input Voltage Surge ratings up to 90V
IOL Tested
Power-over-Ethernet Interface PD Controller
• 1235 Bordeaux Drive, Sunnyvale, CA 94089 • Tel: (408) 222-8888 • FAX: (408) 222-4895 • www.supertex.com
meets IEEE802.3af
Figure 1. Typical Application Circuit
Description
HV110 provides complete power management and
protection for Powered Devices (PDs) utilizing the
IEEE802.3af protocol. As the most complete PD
Power Manager available, HV110 features a 400mA
inrush limit and fault current limit, as well as
minimum current shutdown to ensure additional
protection and reliability to expensive equipments
connected to the PD switch. The internal power
switch uses scaled current-mirror technology which
eliminates the need for an external sense resistor
and provides highly accurate current sensing at the
high and low end operating conditions.
HV110 uses rugged high voltage junction isolated
process, which eliminates the need for any external
high voltage protection devices at the input of these
controllers. Circuit isolation also reduces the chance
of tripping on system noise. A 90V open drain
PWRGD pin provides status information and can be
used to enable the DC/DC power supplies.
HV110 is available in a thermally rugged DPAK-5
package that provides improved thermal resistance
when compared to SO-8 based solutions
TM
Standard
HV110
.
A061104

Related parts for hv110

hv110 Summary of contents

Page 1

... Circuit isolation also reduces the chance of tripping on system noise. A 90V open drain PWRGD pin provides status information and can be used to enable the DC/DC power supplies. HV110 is available in a thermally rugged DPAK-5 package that provides improved thermal resistance when compared to SO-8 based solutions Figure 1. Typical Application Circuit HV110 ...

Page 2

... T Temperature Hysteresis HYS ( 1 ): HV110 will work in both Positive and Negative voltage applications, the maximum differential voltage between the UVLO Threshold to be modified using external resistors, when a zener diode is connected Shorted-circuit timer starts after POR timer Under-current timer starts when I ...

Page 3

... MDIs is called a Midspan PSE. All the specifications for the PSE sitting in the End Point (e.g. the router) may not apply for the Midspan PSE. Even though HV110 device closely associated with the operation of PSE, in fact it is dependent on the PSE for its normal operation. ...

Page 4

... Although not required device, HV110 includes a “minimum circuit breaker” which when the current range less than 20mA will cause a shutdown after the 300ms if the PSE does not react ...

Page 5

... PD Application IEEE Electrical & Timing Requirements Below are of the major features of HV110, some of which are usually found only in PSE devices. Provides an internal current limit for inrush, normal operation and overload conditions. Limits the input current to less than 10µA that will not interfere with Discovery from 2 ...

Page 6

... Figure 5. If the fault is not cleared within the nominal Over- current timer limit of 60ms, HV110 will turn off the a different as per the Figure 4 ...

Page 7

... PD application is well below 180uF so this feature is not of much significance application. Figure 7. HV110 turning 300uF Cport, still maintaining Figure 8. HV110 turning on into a 300uF Cport, the maximum input current of 400mA, does not need any still maintaining the maximum input current of 400mA ...

Page 8

... The diode from base to PWRGD turns off classification as soon as PWRGD is pulled low to save power. The zener in series with the HV110 will keep the Classification components from drawing current until after Discovery. diode in series with the base of the bipolar transistor can block the maximum expected differential network voltage ...

Page 9

... By using a PNP transistor, along with a low power zener and resistor instead, the built-in undervoltage thresholds can be utilized. Figure 10. Powering HV110 using a PNP transistor instead of a zener Figure 10 shows the modified circuit. Discovery stage, the input voltage is less than 10V. pin of the ...

Page 10

... Legal/Disclaimer page on the Supertex website. ©2004 Supertex Inc. All rights reserved. Unauthorized use or reproduction prohibited. Doc. #: DSFP-HV110 The higher voltage rating of HV110, will address any voltage spikes up to 90V without the use of any external Zener diodes for input protection. HV110 ...

Related keywords