CY7C1041BV33 Cypress Semiconductor, CY7C1041BV33 Datasheet - Page 4

no-image

CY7C1041BV33

Manufacturer Part Number
CY7C1041BV33
Description
256K x 16 Static RAM
Manufacturer
Cypress Semiconductor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CY7C1041BV33-15VC
Manufacturer:
CY
Quantity:
1 529
Part Number:
CY7C1041BV33-15ZC
Manufacturer:
CYPRESS
Quantity:
2 195
Part Number:
CY7C1041BV33-15ZC
Manufacturer:
CYPRESS/赛普拉斯
Quantity:
20 000
Company:
Part Number:
CY7C1041BV33-15ZC
Quantity:
601
Part Number:
CY7C1041BV33-20ZI
Manufacturer:
ALTERA
Quantity:
5
Switching Characteristics
Document #: 38-05168 Rev. **
READ CYCLE
t
t
t
t
t
t
t
t
t
t
t
t
t
t
WRITE CYCLE
t
t
t
t
t
t
t
t
t
t
t
Notes:
RC
AA
OHA
ACE
DOE
LZOE
HZOE
LZCE
HZCE
PU
PD
DBE
LZBE
HZBE
WC
SCE
AW
HA
SA
PWE
SD
HD
LZWE
HZWE
BW
4.
5.
6.
7.
8.
Parameter
Test conditions assume signal transition time of 3 ns or less, timing reference levels of 1.5V, input pulse levels of 0 to 3.0V, and output loading of the specified
I
t
At any given temperature and voltage condition, t
The internal write time of the memory is defined by the overlap of CE LOW, and WE LOW. CE and WE must be LOW to initiate a write, and the transition of either of
these signals can terminate the write. The input data set-up and hold timing should be referenced to the leading edge of the signal that terminates the write.
The minimum write cycle time for Write Cycle No. 3 (WE controlled, OE LOW) is the sum of t
OL
HZOE
/I
OH
, t
HZCE
and 30-pF load capacitance.
, and t
Read Cycle Time
Address to Data Valid
Data Hold from Address Change
CE LOW to Data Valid
OE LOW to Data Valid
OE LOW to Low Z
OE HIGH to High Z
CE LOW to Low Z
CE HIGH to High Z
CE LOW to Power-Up
CE HIGH to Power-Down
Byte Enable to Data Valid
Byte Enable to Low Z
Byte Disable to High Z
Write Cycle Time
CE LOW to Write End
Address Set-Up to Write End
Address Hold from Write End
Address Set-Up to Write Start
WE Pulse Width
Data Set-Up to Write End
Data Hold from Write End
WE HIGH to Low Z
WE LOW to High Z
Byte Enable to End of Write
[7, 8]
HZWE
are specified with a load capacitance of 5 pF as in part (b) of AC Test Loads. Transition is measured 500 mV from steady-state voltage.
[4]
[6]
[5, 6]
[6]
[5, 6]
[5, 6]
Description
Over the Operating Range
HZCE
is less than t
LZCE
, t
HZOE
is less than t
Min.
12
12
10
10
10
10
3
0
3
0
0
0
0
7
0
3
LZOE
-12
, and t
HZWE
Max.
12
12
12
6
6
6
6
6
6
HZWE
and t
is less than t
SD
Min.
.
15
15
12
12
12
12
3
0
3
0
0
0
0
8
0
3
-15
LZWE
Max.
15
15
15
7
7
7
7
7
7
for any given device.
CY7C1041BV33
Min.
17
17
12
12
12
12
3
0
3
0
0
0
0
9
0
3
-17
Max.
17
17
17
8
7
7
7
8
8
Page 4 of 11
Unit
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns

Related parts for CY7C1041BV33