AT89C5122 ATMEL [ATMEL Corporation], AT89C5122 Datasheet - Page 88

no-image

AT89C5122

Manufacturer Part Number
AT89C5122
Description
MICROCONTROLLER WITH USB AND SMART CARD READER INTERFACES
Manufacturer
ATMEL [ATMEL Corporation]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT89C5122D-ALRUM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C5122D-RDRIM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C5122D-RDRUM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C5122D-RDVIM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C5122D-SISUM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C5122D-UM
Manufacturer:
MAXIM
Quantity:
1 001
Part Number:
AT89C5122DS-RDTUM
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT89C5122DS-UM
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Table 59. Smart Card Clock Reload Register - SCICLK (S:C1h, SCRS=1)
Reset Value = 0X10 1111b (default value for a divider by two)
DC/DC Converter
Configuration
88
Bit Number
XTSCS
5 - 0
7
7
6
AT8xC5122/23
Bit Mnemonic
SCICLK[5:0]
XTSCS
6
-
-
Description
Smart Card Clock Selection Bit
If XTSCS bit is set OR EXT48 bit is set (in PLLCON register) , CK_PLL is used to generate CK_ISO.
Otherwise, CK_XTAL1 is used to generate CK_ISO.
See the Clock Tree diagram figure 17.
Reserved
The value read from this bit is indeterminate. Do not change these bits.
SCIB clock reload register
Prescaler 2 reload value is used to defines the card clock frequency.
If SCICLK[5:0] is smaller than 48 :
Fck_iso = Fck_pll or Fck_XTAL1/ (2 * (48 - SCICLK[5:0]))
If SCICLK[5:0] is equal to 48 :
Fck_iso = Fck_XTAL1
SCICLK[5:0] must be smaller than 49.
The Smart Card voltage (CVCC) is supplied by the integrated DC/DC converter which is
controlled by several registers:
The DC/DC converter cannot be switched on while the CPRES pin remains inactive. If
CPRES pin becomes inactive while the DC/DC converter is operating an automatic shut
down sequence of the DC/DC converter is initiated by the electronics.
It is mandatory to switch off the DC/DC Converter before entering in Power-down mode.
The DC/DC Converter can work in two different modes which are selected by bit MODE
in DCCKPS register:
The DC/DC clock prescaler which is controlled by bits DCCKPS[3:0], in DCCKPS regis-
ter must be configured to set the DC/DC clock to a working frequency of 4 MHz which
depends upon the value of the crystal. There is no need to change the default configura-
tion set by the reset sequence if an 8 MHz crystal is used by the application.
The DC/DC Converter implements a current overflow controller which avoids permanent
damage of the DC/DC converter in case of short circuit between CVCC and CVSS. The
maximum limit is around 100 mA. It is possible to increase this limit in normal operating
SCICLK5
The SCICR register (Table 44 on page 79) controls the CVCC level by means of bits
VCARD[1:0].
The SCCON register (Table 45 on page 80) enables to switch the DC/DC converter
on or off by means of bit CARDVCC.
The DCCKPS register (Table 61 on page 94) controls the DC/DC clock and current.
Pump Mode: an external inductance of 10 µH must be connected between pins LI
and VCC. VCC can be higher or lower than CVCC.
Regulator mode : no external inductance is required but VCC must be always higher
than CVCC+0.3V. The Regulation mode will work even if an external inductance of
10 µH is connected between pins LI and VCC
5
SCICLK4
4
SCICLK3
3
SCICLK2
2
SCICLK1
1
4202D–SCR–06/05
SCICLK0
0

Related parts for AT89C5122