H3CR-A-300 OMRON [Omron Electronics LLC], H3CR-A-300 Datasheet

no-image

H3CR-A-300

Manufacturer Part Number
H3CR-A-300
Description
Solid-state Multi-functional Timer
Manufacturer
OMRON [Omron Electronics LLC]
Datasheet
DIN 48 x 48-mm State-of-the-art
Multifunctional Timer
• A wider power supply range reduces the number of timer mod-
• A wide range of applications through six or four operating
• Reduced power consumption.
• Enables easy sequence checks through instantaneous outputs
• Length, when panel-mounted with a Socket, of 80 mm or less.
• Time Setting Rings enable consistent settings and limit the set-
• Panel Covers enable various panel designs.
• PNP input models available.
• Rich variety of inputs: Start, reset, and gate functions (11-pin
Model Number Structure
I Model Number Legend
1. Number of Pins
2. Input Type for 11-pin Models
H3CR-A@@@-@
els kept in stock.
modes.
(Except for H3CR-A8E)
for a zero set value at any time range.
ting range.
models and -AP models)
Solid-state Multi-functional Timer
H3CR-A
None: 11-pin models
8:
None: No-voltage input (NPN type)
P:
8-pin models
Voltage input (PNP type)
1 2 3
4
Solid-state Multi-functional Timer
3. Output
4. Suffix
None: Relay output (DPDT)
S:
E:
300: Dual mode models (signal ON/OFF-delay and one-shot)
301: Double time scale (range) models (0.1 s to 600 h)
Transistor output (NPN/PNP universal use)
Relay output (SPDT) with instantaneous relay output (SP-
DT)
H3CR-A
B-109

Related parts for H3CR-A-300

H3CR-A-300 Summary of contents

Page 1

... A wide range of applications through six or four operating modes. • Reduced power consumption. (Except for H3CR-A8E) • Enables easy sequence checks through instantaneous outputs for a zero set value at any time range. • Length, when panel-mounted with a Socket less. ...

Page 2

... D: Signal OFF-delay E: Interval G: Signal ON/OFF-delay J: One-shot H3CR-A Operating mode (see Model note 2) Six multi-modes H3CR-A B2 Dual-modes H3CR-A-300 Six multi-modes H3CR-AP B2 H3CR-A-301 H3CR-AS Operating mode (see Model note 2) Four multi-modes: A, H3CR-A8 B2 (Power supply start) ...

Page 3

... H3CR-A/-AS Operating mode A: ON-delay B: Flicker OFF start B2: Flicker ON start C: Signal ON/OFF-delay D: Signal OFF-delay E: Interval G: Signal ON/OFF-delay (Only for H3CR-A-300) J: One-shot (Only for H3CR-A-300) 11-pin Pin type Input type No-voltage input Time-limit output type H3CR-A/-A8/-AP:Relay output (DPDT) H3CR-AS/-A8S: Transistor output (NPN/PNP universal)* ...

Page 4

... B-112 Solid-state Multi-functional Timer min (min) 0.12 to 1.2 min (min) 0.24 to 2.4 100 to 240 VAC (50/60 Hz)/100 to 125 VDC VAC (50/60 Hz)/ VDC ( VAC/VDC for H3CR- A8E) (see note 2) 85% to 110% of rated supply voltage (90% to 110 VDC) Minimum power-opening time: 0.1 s No-voltage Input ON impedance: 1 kΩ max. ...

Page 5

... Case color Light gray (Munsell 5Y7/1) Degree of protection IP40 (panel surface) Weight Approx Note: 1. The value is ±5% FS +100 ms to −0 ms max. when the mode signal of the H3CR-AP is OFF. 2. Refer to the Life-test Curve. 0.05 s (H3CR-A/-AS times each in 6 directions 2 ...

Page 6

... Solid-state Multi-functional Timer Reference: A maximum current of 0.15 A can be switched at 125 VDC (cosφ and a maximum current of 0.1 A can be switched if L ms. In both cases, a life of 100,000 operations can be expected. The minimum applicable load (100 mA for H3CR-A8E VDC (failure level: P). H3CR-A ...

Page 7

... Input circuit Power-ON indicator Zero setting Time range/ Operating detection unit selectors mode selector circuit Oscillation Counting circuit circuit Input circuit Power-ON indicator Solid-state Multi-functional Timer Output circuit Indicator circuit Output-ON indicator Output circuit Indicator circuit Output-ON indicator H3CR-A B-115 ...

Page 8

... OFF while the reset input is ON. Gate Prohibits time-measurement. Outputs Control output Outputs are turned ON according to designated output mode when preset value is reached. Note: H3CR-AP incorporates start input only. B-116 Solid-state Multi-functional Timer Zero setting Time range/ detection unit selectors ...

Page 9

... Note: Terminals and 8 are empty. Terminals and 10 are the same as for the H3CR-A. H3CR-AP (Contact Output) Power supply Note: Terminal 5 is empty. because its operating mode is six multi-modes (four multi-modes for the H3CR-A8). 8-pin Models H3CR-A8/-A8-301 (Contact Output) Power supply H3CR-A8S (Transistor Output) Power supply Note: Terminals and 5 are empty ...

Page 10

... I Input Connections H3CR-A/-AS The inputs of the H3CR-A/-AS are no-voltage (short-circuit or open) inputs. No-voltage Inputs No-contact Input (Connection to NPN open collector output sensor VDC (sensor power supply power − supply Timer Sensor 5 Gate 6 Start 7 Reset 2 Input (0 V) Operates with transistor ON No-voltage Input Signal Levels No-contact 1 ...

Page 11

... H3CR-AP The start input of the H3CR-AP is voltage input. (Voltage imposition or open) Voltage Inputs No-contact Input (Connection to PNP open collector output sensor VDC (sensor power supply power − supply Sensor Timer 10 Power supply (+) 6 Start 7 Input 0V 2 Power supply (−) Operates with PNP transistor ON ...

Page 12

... The minimum input pulse width (for start, reset The letter “t” in the timing charts stands for the set time and “t–a” means that the period is less than the time set. 4. Power supply start in mode J is also possible for H3CR-A8/-A8E/-A8S/-A8-301 models. H3CR-A/-AS/-AP* *H3CR-AP model incorporates start input only ...

Page 13

... OFF Output ON relay OFF Note: 1. This timing chart indicates the gate input in op- erating mode A (ON-delay operation). 2. The set time is the sum H3CR-AP model incorporates start input only. Timing chart Basic operation Power (see note) Output 1±0.6 s (Fixed) and t 2 ...

Page 14

... The letter “t” in the timing charts stands for the set time and “t–a” means that the period is less than the time set. B-122 Solid-state Multi-functional Timer Timing chart Basic operation Power Output Basic operation Power Output Basic operation Power Output 1±0.6 s Power (Fixed) Output H3CR Basic operation 1±0 (Fixed) ...

Page 15

... The letter “t” in the timing charts stands for the set time and “t–a” means that the period is less than the time set. Timing chart Basic operation Power t Output Basic operation Power t t Output Basic operation Power t Output (Fixed) Basic operation Power t Output H3CR-A Solid-state Multi-functional Timer t t 1±0.6 s (Fixed) B-123 ...

Page 16

... Operating mode display window Operating mode selector Select a mode from B2 and E (H3CR-A, -AP, and -AS) A, B2, E and J (H3CR-A8, -A8S, and -A8E) G and J (H3CR-A-300) Scale range display windows Time unit display window Time unit selector (select one Time setting from sec, min, hrs, and 10h) ...

Page 17

... These dimensions vary with the kind of DIN track (reference value dia dia dia. 50 Time Setting Panel cover Ring Dimensions with Back Connecting Socket P3G-08/P3GA-11 81 H3CR-A 87.6 H3CR-AS H3CR-AP + Adapter P3GA-11 Y92F-30 (When Y92A-48G P2CF-08 * 2.3 mounted) Solid-state Multi-functional Timer 66.6 52.3 0.7 44.8 x 44.8 11 pins 66.6 52.3 0.7 44 ...

Page 18

... Application Examples (H3CR-A) A Mode: ON-delay ON-delay operation (A mode basic mode. 1. Power-ON Start/Power-OFF Reset The Power-ON start/Power-OFF reset operation is a standard oper- ating method Power (2 and 10) Start (2 and 6) Reset (2 and 7) Control output and 11 and 4) Control output and 11) ...

Page 19

... Control output and 11 and 4) Control output and 11 and 3) Power indicator Solid-state Multi-functional Timer Start signal (The operation starts with the signal ON or OFF) Power supply (Power continuously supplied) Lit Flashing Lit Start signal (NC to NO) Power supply H3CR-A B-127 ...

Page 20

... Time-limit Reset This function is useful for the repetitive control such as the filling of liquid for a specified period after each Signal start input. Control output and 11) Control output and 11) Flashing Lit H3CR Power (2 and 10) Start (2 and and and 3) ...

Page 21

... Precautions (H3CR-A) Note: The undermentioned is common for all H3CR-A models. I Power Supplies For the power supply of an input device of the H3CR-A@/-A@S/-AP , use an isolating transformer with the primary and secondary wind- ings mutually isolated and the secondary winding not grounded. Example: H3CR-A ...

Page 22

... H3CR-A 2 Common to All H3CR-A Models With the H3CR-AP , input wires must be as short as possible. If the floating capacity of wires exceeds 1,200 pF (approx for cables with 120 pF/m), the operation will be affected. Pay particular atten- tion when using shielded cables. The H3CR-A@S transistor output is isolated from the internal cir- cuitry by a photocoupler ...