EDS11-101E FUJI [Fuji Electric], EDS11-101E Datasheet

no-image

EDS11-101E

Manufacturer Part Number
EDS11-101E
Description
FC SERIES COMPACT CONTROLLER S(STEP OUTPUT TYPE)
Manufacturer
FUJI [Fuji Electric]
Datasheet
FEATURES
1. PID auto turing function
2. High reliability
3. All operations are performed from the front of the panel
4. Transmission function
FUNCTIONAL DIAGRAM
External set point input
(CAS)
single-loop controller using a microprocessor.
couple and resistance bulbs as input, and includes sufficient
control and computation functions which permit composition
of a flexible system for PID control, square-root extraction,
non-linear control, etc.
DATA SHEET
Remote acknowledge
signal (DI3)
Valve position input
(W
Process value input
(PV)
Optimum PID parameter can be obtained for processing.
LED's (red and green) are used for the bar graph indicator
and for parameter indication (red). A non-volatile memory
retains the control and computation parameters even if
power should be interrupted.
Operations such as parameter setting, auto/manual
changeover are performed from the front of the panel.
Incorporation of transmission function permits setting of
concentrated monitoring data at the host system.
Compact controller S (fixed function type) is a compact
It accepts uniform signals, and signals from a thermo-
0
Manual mode
command (SMV)
PV tracking (DI1)
)
Pulse input (PI)
: Option
4 to 20mA,
thermocouple/
resistance bulb
conversion
FC SERIES COMPACT CONTROLLER S
(STEP OUTPUT TYPE)
Opening/resistance
conversion
Communication
terminal
Linearize
M mode
SH
SL
Square-root
extraction
Personal computer
A.M
R
Filter
Non-linear
R
To other controllers
P
D
I
H
MV
R mode
L
Fault
Pulse width
conversion
L or SCC mode
M mode
Alarm
R .A
M
Bar graph indicator
FLT lamp
H lamp
L lamp
Date
EDS11-101e
Control output
(pulse width) (PO)
Valve position output
(voltage) (AO1)
Compensated PV
signal output (KPV)
Set point transmit
signal output (SV)
Manual mode output
(M)
Local mode output
(DO1)
Remote request
(R-REQ)
Fault output (FLT)
High alarm
output (H)
Low alarm
output (L)
PNC1
Jan. 27, 1999

Related parts for EDS11-101E

EDS11-101E Summary of contents

Page 1

... Valve position output (voltage) (AO1) Compensated PV signal output (KPV) Set point transmit signal output (SV) Manual mode output M mode (M) Local mode output (DO1) Remote request (R-REQ) Fault output (FLT) High alarm output (H) Low alarm output (L) FLT lamp H lamp Alarm L lamp EDS11-101e Date Jan. 27, 1999 ...

Page 2

PNC1 SPECIFICATIONS 1. Control functions PID control: Proportional band (P); 1.0 to 3276.7% Integration time (I); 0.1 to 3276.7 sec Derivative time (D); 0.0 to 900.0 sec PID auto tuning function Additional function: Segmented line approximation; 15 seg- mented lines ...

Page 3

Power failure processing functions Power failure detection: Control stoppage at power failure detec- tion During power failure: Operating parameters backed up by ca- pacitor when power faulure occurs wthin 5 minutes Initial set point and manipulated output values, PID ...

Page 4

PNC1 CODE SYMBOLS Process variable input signal 20mA DC J thermocouple C ...

Page 5

CONNECTION DIAGRAM Block terminals (M4 screws (Process (PV) value input – (SC (Manual mode) 33 PI– (Local mode FLT SMV ...

Page 6

PNC1 Transmission connector SIG GND 1 (VST SHLD 7 3 INH 8 RXD+ 4 TXD+ 9 RXD– 5 TXD– Yellow Green Brown Red SIG GND 1 (VST SHLD 7 3 INH 8 RXD+ 4 TXD+ 9 ...