Datasheet
manual control type and a remote control type used in com-
bination with a compact controller.
pushbutton operation circuit to provide easy readouts and
handling for process operation by man-machine communi-
cation.
bulb or 4 to 20mA input optionally.
FEATURES
1. High reliability
2. Application of international standards
3. Front panel operation
FUNCTIONAL DIAGRAM
External MV input
DATA SHEET
The FC series manual loader is available in two types, a
This instrument is equipped with a solid state indicator and
It can be directly connected to a thermocouple, resistance
The manual loader is a solid state instrument having few
mechanical parts. The indicator and other units which
formerly consisted of mechanical parts are also designed
with solid state circuits to provide high reliability.
The instrument is compact, and the external dimensions
comply with international IEC. The power supply and
signal also comply with IEC standards (24V, 1 to 5V DC).
Operation on 100V or 200V AC power supply is possible.
Process values, valve position input, etc. can be read
accurately from the digital display on the panel front.
Parameter setting and manual operation are also possible
from the front of the panel.
Process value
input (PV)
Valve position
input (W)
Manual mode
command
(SMV)
(PI)
Linearize
FC SERIES MANUAL LOADER
(STEP OUTPUT TYPE)
Square-root
extraction
W/V
Filter
PV
MV
Limiter
H
L
KPV
MV
M
A
ALM
Date
EDS11-104e
Manual mode
output (M)
Compensated
process value
signal (KPV)
Manipulated
output
(pulse width)
(PO)
High alarm
output (H)
Low alarm
output (L)
PND1
Jan. 27, 1999

Related parts for EDS11-104E

EDS11-104E Summary of contents

Page 1

... Process value input (PV) External MV input (PI) Valve position input (W) Manual mode command (SMV Filter Limiter H W/V L PND1 Manual mode output (M) Compensated process value signal (KPV) Manipulated A output M (pulse width) (PO) MV High alarm output (H) KPV ALM Low alarm output (L) EDS11-104e Date Jan. 27, 1999 ...

Page 2

PND1 SPECIFICATIONS 1. Input signal (1) Process value input signal: One point of signal select from the follow- ing inputs Voltage in- Input resistance put signal more than 1M Current in- 24V DC power sup- 4 ...

Page 3

Dielectric strength: 1500V AC, 1 min. Insulation resistance: 100M or more at 500V DC Ambient temperature Ambient humidity: 90 less Enclosure: Steel case Nameplate: 100 ( (W) mm, white acryl Dimensions: 144 ...

Page 4

PND1 CONNECTION DIAGRAM Block terminal (M4 screws (PV) Process value 31 input I– 12 (SC (Manual mode SMV 15 (Manual mode command Instrument power (AC) Process value ...

Related keywords