EDS11-105E FUJI [Fuji Electric], EDS11-105E Datasheet

no-image

EDS11-105E

Manufacturer Part Number
EDS11-105E
Description
FC SERIES SETTER (CONTINUOUS OUTPUT TYPE)
Manufacturer
FUJI [Fuji Electric]
Datasheet
Process value
External set point
pulse width,
or pulse number)
Remote
acknowledege
signal (R-ACK)
nput (PV)
nput (CAS or PI)
1 to 5V DC,
troller or variable constant setting of various types of com-
puting elements.
pushbutton operation system to provide reliable monitoring
and operating functions.
FEATURES
1. High reliability
2. International standards
3. Front panel operation
FUNCTIONAL DIAGRAM
DATA SHEET
This instrument uses a solid state indicator and a
The FC series setter is used for remote setting of a con-
This instrument is designed with few mechanical parts.
It is mainly composed of electronic parts such as a solid
state indicator which was formerly consisted of mechani-
cal parts.
This instrument is compact in size, conforming to inter-
national standards IEC. It operates on 24V DC power to
deliver 1 to 5V DC signals as recommended by IEC
standards.
100 and 200V AC power are also available for conven-
ience of operation.
Process values and set points can be read accurately with
digital indications on panel front. Various parameter set-
tings and setting operations are also possible from the
front panel of the instrument.
FC SERIES SETTER (CONTINUOUS OUTPUT TYPE)
Linearize
Square-root
extraction
Filter
Limiter
H
L
SV
R
L
PV
SV
KPV
FAULT
ALM
Date
Local mode
output (LS)
Remote request
(R-REQ)
Compensated
process
value signal
(KPV)
Set point
output signal
(SV)
FLT output
High alarm
output (H)
Low alarm
output (L)
EDS11-105e
PNF1
Jul. 1, 1994

Related parts for EDS11-105E

EDS11-105E Summary of contents

Page 1

... Remote acknowledege signal (R-ACK Filter Limiter KPV PNF1 Local mode output (LS) Remote request (R-REQ) Compensated process value signal (KPV) Set point output signal (SV) FLT output FAULT High alarm output (H) ALM Low alarm output (L) EDS11-105e Date Jul. 1, 1994 ...

Page 2

PNF1 SPECIFICATIONS 1. Input signal (1) Process value input signal: One input selectable from the following Voltage in Input resistance, I put signal + 1M or more I 0 current in 20mA DC 24V ...

Page 3

Communication interface (a) T-link: Private interface Transmission speed: 500Kbps No. of units connectable: 32 max. Transmission distance: 1km max. Transmission form: Multi-drop Control method: I/O transmission and message (b) RS-422A/485: Universal interface Transmission speed: 2400, 4800, 9600 or 19200bps ...

Page 4

PNF1 OUTLINE DIAGRAM (Unit:mm) Terminal Terminal cover 140 36 Panel cutout When mounting 1unit +0 Panel thickness 8mm or less Mounting Support bracket 200min. bracket 355 When mounting "n" units +1 (72.2n – No. ...

Page 5

CONNECTION DIAGRAM Block terminals (M4 screw (PV) Process value input I– 12 (SC – (Local mode FLT Instrument power ...

Page 6

PNF1 COMMUNICATION CONNECTOR 1 SIG GND 6 2 SHLD(SD INH 8 RXD + 4 TXD+(T1) 9 RXD – 5 TXD–(T2) Yellow Green Brown Red 1 SIG GND 6 2 SHLD(SD INH 8 RXD + 4 TXD+(T1) ...