M24256-BWDW6TP STMicroelectronics, M24256-BWDW6TP Datasheet - Page 21

IC EEPROM 256KBIT 400KHZ 8TSSOP

M24256-BWDW6TP

Manufacturer Part Number
M24256-BWDW6TP
Description
IC EEPROM 256KBIT 400KHZ 8TSSOP
Manufacturer
STMicroelectronics
Datasheet

Specifications of M24256-BWDW6TP

Format - Memory
EEPROMs - Serial
Memory Type
EEPROM
Memory Size
256K (32K x 8)
Speed
400kHz
Interface
I²C, 2-Wire Serial
Voltage - Supply
2.5 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Package / Case
8-TSSOP
Density
256Kb
Interface Type
Serial (I2C)
Organization
32Kx8
Access Time (max)
900ns
Frequency (max)
400KHz
Write Protection
Yes
Data Retention
40Year
Operating Supply Voltage (typ)
3.3/5V
Package Type
TSSOP
Operating Temp Range
-40C to 85C
Supply Current
2mA
Operating Supply Voltage (min)
2.5V
Operating Supply Voltage (max)
5.5V
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
8
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-8622-2
M24256-BWDW6TP

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M24256-BWDW6TP
Manufacturer:
TI
Quantity:
12 400
Part Number:
M24256-BWDW6TP
Manufacturer:
ST
Quantity:
20 000
Part Number:
M24256-BWDW6TP@@@@@@
Manufacturer:
ST
0
M24256-BF, M24256-BR, M24256-BW, M24256-DR
3.18
3.19
Reading the lock status (M24256-D only)
The locked/unlocked status of the Identification page can be checked by transmitting a
specific truncated command [Identification Page Write instruction + one data byte] to the
device. The device will return an acknowledge bit if the Identification page is unlocked,
otherwise a NoAck bit if the Identification page is locked.
Right after this, it is recommended to transmit to the device a Start condition followed by a
Stop condition, so that:
Acknowledge in Read mode
For all Read instructions, the device waits, after each byte read, for an acknowledgment
during the 9
time, the device terminates the data transfer and switches to its Standby mode.
Start: the truncated command is not executed because the Start condition resets the
device internal logic,
Stop: the device is then set back into Standby mode by the Stop condition.
th
bit time. If the bus master does not drive Serial Data (SDA) Low during this
Doc ID 6757 Rev 23
Device operation
21/42

Related parts for M24256-BWDW6TP