M24C64-WBN6P STMicroelectronics, M24C64-WBN6P Datasheet - Page 22

IC EEPROM 64KBIT 400KHZ 8DIP

M24C64-WBN6P

Manufacturer Part Number
M24C64-WBN6P
Description
IC EEPROM 64KBIT 400KHZ 8DIP
Manufacturer
STMicroelectronics
Datasheet

Specifications of M24C64-WBN6P

Format - Memory
EEPROMs - Serial
Memory Type
EEPROM
Memory Size
64K (8K x 8)
Speed
400kHz
Interface
I²C, 2-Wire Serial
Voltage - Supply
2.5 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Package / Case
8-DIP (0.300", 7.62mm)
Organization
8 K x 8
Interface Type
I2C
Maximum Clock Frequency
0.4 MHz
Access Time
900 ns
Supply Voltage (max)
5.5 V
Supply Voltage (min)
2.5 V
Maximum Operating Current
2 mA
Maximum Operating Temperature
+ 85 C
Mounting Style
Through Hole
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
2.5 V, 5.5 V
Memory Organization
8K X 8
Clock Speed
400MHz
No. Of Pins
8
Operating Temperature Range
-40°C To +85°C
Ic Generic Number
24C64
Memory Voltage, Vcc
2.5V
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-8575
M24C64-WBN6P

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M24C64-WBN6P
Manufacturer:
SIMCOM
Quantity:
1 000
Part Number:
M24C64-WBN6P
Manufacturer:
ST
0
Device operation
4.18
4.19
22/44
Read the lock status (M24C64-D)
The locked/unlocked status of the Identification page can be checked by issuing a specific
truncated command [Identification Page Write instruction + one data byte]: this data byte will
be acknowledged if the Identification page is unlocked, while it will not be acknowledged if
the Identification page is locked.
Once the acknowledge bit of this data byte is read, it is recommended to generate a Start
condition followed by a Stop condition, so that:
Acknowledge in Read mode
For all Read commands, the device waits, after each byte read, for an acknowledgment
during the 9
time, the device terminates the data transfer and switches to its Standby mode.
The instruction is truncated and not executed as the Start condition resets the device
internal logic.
The device is set back into Standby mode by the Stop condition.
th
bit time. If the bus master does not drive Serial Data (SDA) low during this
Doc ID 16891 Rev 23
M24C64-DF, M24C64-W, M24C64-R, M24C64-F