M29F032D70N6T NUMONYX, M29F032D70N6T Datasheet - Page 14

no-image

M29F032D70N6T

Manufacturer Part Number
M29F032D70N6T
Description
IC FLASH 32MBIT 70NS 40TSOP
Manufacturer
NUMONYX
Datasheet

Specifications of M29F032D70N6T

Format - Memory
FLASH
Memory Type
FLASH
Memory Size
32M (4M x 8)
Speed
70ns
Interface
Parallel
Voltage - Supply
4.5 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Package / Case
40-TSOP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
497-1702-2
M29F032D
commands must be used to set all the bits in a
block or in the whole memory from ’0’ to ’1’.
Erase Timer Bit (DQ3). The Erase Timer Bit can
be used to identify the start of Program/Erase
Controller operation during a Block Erase com-
mand. Once the Program/Erase Controller starts
erasing the Erase Timer Bit is set to ’1’. Before the
Program/Erase Controller starts the Erase Timer
Bit is set to ’0’ and additional blocks to be erased
may be written to the Command Interface. The
Erase Timer Bit is output on DQ3 when the Status
Register is read.
Alternative Toggle Bit (DQ2). The
Toggle Bit can be used to monitor the Program/
Erase controller during Erase operations. The Al-
ternative Toggle Bit is output on DQ2 when the
Status Register is read.
During Chip Erase and Block Erase operations the
Toggle Bit changes from ’0’ to ’1’ to ’0’, etc., with
successive Bus Read operations from addresses
Table 5. Status Register Bits
Note: Unspecified data bits should be ignored.
14/36
Program
Program During Erase
Suspend
Program Error
Chip Erase
Block Erase before
timeout
Block Erase
Erase Suspend
Erase Error
Operation
Faulty Block Address
Good Block Address
Non-Erasing Block
Non-Erasing Block
Non-Erasing Block
Erasing Block
Erasing Block
Erasing Block
Any Address
Any Address
Any Address
Any Address
Address
Alternative
DQ7
DQ7
DQ7
DQ7
0
0
0
0
0
1
0
0
within the blocks being erased. A protected block
is treated the same as a block not being erased.
Once the operation completes the memory returns
to Read mode.
During Erase Suspend the Alternative Toggle Bit
changes from ’0’ to ’1’ to ’0’, etc. with successive
Bus Read operations from addresses within the
blocks being erased. Bus Read operations to ad-
dresses within blocks not being erased will output
the memory cell data as if in Read mode.
After an Erase operation that causes the Error Bit
to be set the Alternative Toggle Bit can be used to
identify which block or blocks have caused the er-
ror. The Alternative Toggle Bit changes from ’0’ to
’1’ to ’0’, etc. with successive Bus Read Opera-
tions from addresses within blocks that have not
erased correctly. The Alternative Toggle Bit does
not change if the addressed block has erased cor-
rectly.
No Toggle
Toggle
Toggle
Toggle
Toggle
Toggle
Toggle
Toggle
Toggle
Toggle
Toggle
DQ6
Data read as normal
DQ5
0
0
1
0
0
0
0
0
0
1
1
DQ3
1
0
0
1
1
1
1
No Toggle
No Toggle
No Toggle
Toggle
Toggle
Toggle
Toggle
Toggle
DQ2
RB
0
0
0
0
0
0
0
0
1
1
0
0

Related parts for M29F032D70N6T