Datasheet

Specifications of EPCS64SI16N

Programmable Type
In System Programmable
Memory Size
64Mb
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Package / Case
16-SOIC (0.300", 7.50mm Width)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
544-1380-5
EPCS64SI16
EPCS64SI16N

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EPCS64SI16N
Manufacturer:
ALTERA
Quantity:
1 290
Part Number:
EPCS64SI16N
Manufacturer:
ALTERA
Quantity:
4
Part Number:
EPCS64SI16N
Manufacturer:
ALTERA42
Quantity:
696
Part Number:
EPCS64SI16N
Manufacturer:
ALTERA
Quantity:
6 000
Part Number:
EPCS64SI16N
Manufacturer:
ALTERA
Quantity:
6 000
Part Number:
EPCS64SI16N
Manufacturer:
XILINX
0
Part Number:
EPCS64SI16N
Manufacturer:
ALTERA
0
Part Number:
EPCS64SI16N
Manufacturer:
ALTERA
Quantity:
20 000
Part Number:
EPCS64SI16N
0
Company:
Part Number:
EPCS64SI16N
Quantity:
18
Part Number:
EPCS64SI16NALTERA
Manufacturer:
ALTERA
0
Chapter 3: Serial Configuration Devices (EPCS1, EPCS4, EPCS16, EPCS64, and EPCS128) Data Sheet
Serial Configuration Device Memory Access
Figure 3–9. Read Status Operation Timing Diagram
Figure 3–10. Write Status Operation Timing Diagram
© December 2009
DCLK
DATA
ASDI
nCS
Altera Corporation
Write Status Operation
The write status operation code is b'0000 0001, with the MSB listed first. Use the
write status operation to set the status register block protection bits. The write status
operation has no effect on the other bits. Therefore, you can implement this operation
to protect certain memory sectors, as defined in
setting the block protect bits, the protected memory sectors are treated as read-only
memory. You must execute the write enable operation before the write status
operation so the device sets the status register’s write enable latch bit to 1.
The write status operation is implemented by driving nCS low, followed by shifting in
the write status operation code and one data byte for the status register on the ASDI
pin.
driven high after the eighth bit of the data byte has been latched in, otherwise, the
write status operation is not executed.
Immediately after nCS drives high, the device initiates the self-timed write status
cycle. The self-timed write status cycle usually takes 5 ms for all serial configuration
devices and is guaranteed to be less than 15 ms (refer to t
account for this delay to ensure that the status register is written with desired block
protect bits. Alternatively, you can check the write in progress bit in the status register
by executing the read status operation while the self-timed write status cycle is in
progress. The write in progress bit is 1 during the self-timed write status cycle, and 0
when it is complete.
DCLK
DATA
ASDI
nCS
0
Figure 3–10
High Impedance
1
2
Operation Code
3
0
4
High Impedance
1
shows the timing diagram for the write status operation. nCS must be
5
2
6
Operation Code
3
7
MSB
4
7
8
5
6
9
6
Status Register Out
5
10
7
4
11
MSB
7
8
3
12
6
9
2
13
5
10
1
14
Status Register
4
11
0
15
MSB
3
12
7
Configuration Handbook (Complete Two-Volume Set)
Table 3–9
2
13
6
1
14
5
Status Register Out
0
15
4
WS
through
3
in
2
Table
1
Table
0
3–16). You must
7
3–13. After
3–19

Related parts for EPCS64SI16N