IRS2336SPBF International Rectifier, IRS2336SPBF Datasheet - Page 25

no-image

IRS2336SPBF

Manufacturer Part Number
IRS2336SPBF
Description
IC DRIVER BRIDGE 3-PHASE 28-SOIC
Manufacturer
International Rectifier
Datasheet

Specifications of IRS2336SPBF

Configuration
3 Phase Bridge
Input Type
Differential
Delay Time
530ns
Current - Peak
200mA
Number Of Configurations
1
Number Of Outputs
3
High Side Voltage - Max (bootstrap)
600V
Voltage - Supply
10 V ~ 20 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
28-SOIC (7.5mm Width)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Over-Current Protection
The IRS2336xD HVICs are equipped with an ITRIP input pin. This functionality can be used to detect over-current
events in the DC- bus. Once the HVIC detects an over-current event through the ITRIP pin, the outputs are
shutdown, a fault is reported through the FAULT pin, and RCIN is pulled to V
The level of current at which the over-current protection is initiated is determined by the resistor network (i.e., R
and R
determine the maximum allowable level of current in the DC- bus and select R
node V
For example, a typical value for resistor R
exceed 5 V; if necessary, an external voltage clamp may be used.
Over-Temperature Shutdown Protection
The ITRIP input of the IRS2336xD can also be used to detect over-temperature events in the system and initiate a
shutdown of the HVIC (and power switches) at that time. In order to use this functionality, the circuit designer will
need to design the resistor network as shown in Figure 15 and select the maximum allowable temperature.
This network consists of a thermistor and two standard resistors R
resistance of the thermistor will change; this will result in a change of voltage at node V
be selected such the voltage V
the maximum allowable temperature is reached. The voltage of the ITRIP pin should not be allowed to exceed 5 V.
(e.g., DL4148) can be used. This network is shown in Figure 16; the OR-ing diodes have been labeled D
When using both the over-current protection and over-temperature protection with the ITRIP input, OR-ing diodes
www.irf.com
2
) connected to ITRIP as shown in Figure 14, and the ITRIP threshold (V
X
reaches the over-current threshold (V
Figure 14: Programming the over-current protection
X
should reach the threshold voltage (V
0
could be 50 m . The voltage of the ITRIP pin should not be allowed to
V
IT,TH+
IT,TH+
) at that current level.
= R
0
I
DC-
25
(R
1
/(R
1
+R
2
IT,TH+
))
3
and R
) of the ITRIP functionality by the time that
SS
IRS2336x(D) Family
.
IT,TH+
4
0
. As the temperature changes, the
, R
). The circuit designer will need to
1
, and R
X
. The resistor values should
2
© 2009 International Rectifier
such that the voltage at