BTS442E2 E3062A Infineon Technologies, BTS442E2 E3062A Datasheet - Page 4

no-image

BTS442E2 E3062A

Manufacturer Part Number
BTS442E2 E3062A
Description
IC HIGH SIDE PWR SWITCH TO220-5
Manufacturer
Infineon Technologies
Series
PROFET®r
Type
High Sider
Datasheet

Specifications of BTS442E2 E3062A

Input Type
Non-Inverting
Number Of Outputs
1
On-state Resistance
15 mOhm
Current - Output / Channel
21A
Current - Peak Output
95A
Voltage - Supply
4.5 V ~ 42 V
Operating Temperature
-40°C ~ 150°C
Mounting Type
Surface Mount
Package / Case
TO-220-5 (Bent and Staggered Leads)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
BTS442E2E3062ANT
BTS442E2E3062AT
SP000011263
Parameter and Conditions
at T
Protection Functions
Initial peak short circuit current limit (pin 3 to 5)
( max 400 µs if V
Repetitive short circuit current limit
Short circuit shutdown delay after input pos. slope
Output clamp (inductive load switch off)
Short circuit shutdown detection voltage
Thermal overload trip temperature
Thermal hysteresis
Inductive load switch-off energy dissipation
Reverse battery (pin 3 to 1)
Integrated resistor in V
Diagnostic Characteristics
Open load detection current
8
9
10)
11
Data Sheet
)
)
min value valid only, if input "low" time exceeds 30 µs
V
at V
T
) Reverse load current (through intrinsic drain-source diode) is normally limited by the connected load.
(pin 3 to 5)
j Start
(on-condition)
ON
j
Integrated protection functions are designed to prevent IC destruction under fault conditions described in the
data sheet. Fault conditions are considered as "outside" normal operating range. Protection functions are not
designed for continuous repetitive operation.
Short circuit current limit for max. duration of t
While demagnetizing load inductance, dissipated energy in PROFET is E
E
Reverse current I
these condition is dependent on the size of the heatsink. Reverse I
external GND-resistor (150 Ω). Input and Status currents have to be limited (see max. ratings page 2 and
circuit page 7).
= 25 °C, V
T
AS
OUT
> V
j
= T
=
= 150 °C, single pulse
1
ON(SC)
= V
/
jt
2
* L * I
(see timing diagrams, page 10)
bb
bb
,
- V
= 12 V unless otherwise specified
2
L
ON
* (
ON(CL) ,
GND
V
> V
ON(CL)
V
of ≈ 0.3 A at V
8)
ON(CL)
bb
ON(SC)
I
L
line
- V
= 30 mA
bb
11
)
), see diagram page 8.
)
bb
T
= -32 V through the logic heats up the device. Time allowed under
j
=-40..+150°C:
T
j
=25..150°C:
T
V
V
j
T
T
bb
bb
=+150°C:
d(SC) max
T
j
j
=-40 °C
j
=-40°C:
10)
= 12 V:
= 24 V:
=25°C:
4
,
9
)
,
=400 µs, prior to shutdown
:
I
I
t
V
V
T
E
E
E
-V
R
I
Symbol
L(SCp)
L(SCr)
d(SC)
L (OL)
jt
T
ON(CL)
ON(SC)
AS
Load12
Load24
bb
bb
jt
GND
can be reduced by an additional
AS
PROFET® BTS 442 E2
=
150
min
45
30
80
--
--
--
--
--
--
--
--
2
2
V
ON(CL)
Values
120
8.3
typ
95
70
58
10
* i
--
--
--
--
--
--
--
--
L
(t) dt, approx.
2010-Jan-26
1900
1500
max
140
400
2.1
1.7
1.2
32
--
--
--
--
--
--
--
--
Unit
mA
°C
µs
A
A
V
V
K
V
J

Related parts for BTS442E2 E3062A