MC10XS3435BPNA Freescale Semiconductor, MC10XS3435BPNA Datasheet - Page 31

no-image

MC10XS3435BPNA

Manufacturer Part Number
MC10XS3435BPNA
Description
IC SWITCH HIGH SIDE QUAD 24-QFN
Manufacturer
Freescale Semiconductor
Type
High Side Switchr
Datasheet

Specifications of MC10XS3435BPNA

Number Of Outputs
4
Rds (on)
2 x 10 mOhm, 2 x 35 mOhm
Internal Switch(s)
Yes
Current Limit
5A
Voltage - Input
6 ~ 20 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
24-QFN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC10XS3435BPNA
Manufacturer:
Freescale Semiconductor
Quantity:
135
Part Number:
MC10XS3435BPNA
Manufacturer:
FREESCALE
Quantity:
4 407
Part Number:
MC10XS3435BPNA
Manufacturer:
FREESCALE
Quantity:
4 407
START-UP SEQUENCE
following sequence is provided:
set to logic [1]) with an external reference clock:
function is not guaranteed.
PROTECTIONS
Over-temperature Fault
and shutdown circuitry for each output structure.
temperature is higher than T
register will be set to [1]. The fault bits will be cleared in the
status register after a SPI read command.
Over-current Fault
protect each output structure against resistive short-circuit
condition. This protection is composed by eight predefined
current levels (time dependent) to fit Xenon-HID manners by
default or, 55 W or 28 W bulb profiles, selectable separately
by Xenon bit and 28 W bits (as illustrated
37).
Analog Integrated Circuit Device Data
Freescale Semiconductor
The 10XS3435 enters in Normal mode after start-up if
•VPWR and VDD power supplies must be above their
•generate wake-up event (wake-up=1) from 0 to 1 on
•toggle WD bit from 0 to 1.
And, in case of the PWM module is used (PWM_en bit is
•apply PWM clock on IN0 input pin after maximum 200 μs
If the correct start-up sequence is not provided, the PWM
The 10XS3435 incorporates over-temperature detection
Two cases need to be considered when the output
The 10XS3435 incorporates output shutdown in order to
•If the output command is ON: the corresponding output is
•If the output command is OFF: FS will go to logic [0] till
For both cases, the fault register OT[0:3] bit into the status
under-voltage thresholds,
RSTB. The device switches to normal mode with SPI
register content is reset (as defined in
Table
after 50 μs typical, and all SPI registers are set to
default values (set to logic [0]).
(min. 50 μs).
latched OFF. FS will be also latched to logic [0]. To
delatch the fault and be able to turn ON again the
outputs, the failure condition must disappear and the
autoretry circuitry must be active or the corresponding
output must be commanded OFF and then ON (toggling
fault_control signal of corresponding output) or
V
the corresponding output temperature will be below
T
SD
SUPPLY(POR)
.
23). All features of the 10XS3435 will be available
condition if V
SD
:
DD
= 0.
PROTECTION AND DIAGNOSTIC FEATURES
Figure
Table 11
14, page
and
will be huge. fault_control signal transition from logic [0] to [1]
or an autoretry define this event. In this case, the over-current
protection will be fitted to inrush current, as shown in
Figure
OC[1:0] bits select over-current slope speed and OCHI1
current step can be removed in case of OCHI bit is set to [1].
OCLO2 current level by default. Three other DC over-current
levels are available: OCLO1 or OCLO3 or OCLO4 based on
the state of the OCLO[1,0] bits.
detection level, the corresponding output will latch the output
OFF and FS will be also latched to logic [0]. To delatch the
fault and be able to turn ON again the corresponding output,
the failure condition must disappear and the autoretry
In the first turn-on, the lamp filament is cold and the current
In steady state, the wire harness will be protected by
If the load current level ever reaches the over-current
hson signal
PWM
fault_control
hson
Over-current thresholds
5. This over-current protection is programmable:
PROTECTION AND DIAGNOSTIC FEATURES
FUNCTIONAL DEVICE OPERATION
10XS3435
31