IR3084UMTRPBF International Rectifier, IR3084UMTRPBF Datasheet - Page 23

no-image

IR3084UMTRPBF

Manufacturer Part Number
IR3084UMTRPBF
Description
IC CTLR XPHASE 28-MLPQ
Manufacturer
International Rectifier
Series
XPhase™r
Datasheet

Specifications of IR3084UMTRPBF

Package / Case
28-MLPQ
Mounting Type
Surface Mount
Current - Supply
14mA
Voltage - Supply
9.5 V ~ 16 V
Operating Temperature
0°C ~ 100°C
Applications
Processor
Package
28-Lead MLPQ
Circuit
X-Phase Control IC
Switch Freq (khz)
150kHz to 1.0MHz
Pbf
PbF Option Available
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IR3084UMTRPBF
Manufacturer:
IR
Quantity:
470
Part Number:
IR3084UMTRPBF
Manufacturer:
IR
Quantity:
2 559
IR3084U
Under Voltage Lockout (UVLO)
The UVLO function monitors the IR3084U’s VCC supply pin and ensures that there is adequate voltage to safely
power the internal circuitry. The IR3084U’s UVLO is set higher than the minimum operating voltage of compatible
Phase ICs thus providing UVLO protection for them as well. UVLO at the Phase ICs is a function of the Error
Amplifier’s output voltage. When the IR3084U is in UVLO, the Error Amplifier is disabled and EAOUT is at a very
low voltage (<200mV) thus preventing the Phase ICs from becoming active.
During power-up the fault latch will be reset when VCC exceeds 9.9V and there are no other faults. If the VCC
voltage drops below 9.1V the fault latch will be set.
Over Current Protection (OCP)
The current limit threshold is set by a resistor connected between the OCSET and VDAC pins. If the IIN pin
voltage, which is proportional to the average phase current plus DAC voltage, exceeds the OCSET voltage, the
over-current protection is triggered.
VID = Fault Code (NO_CPU)
When VIDSEL is grounded or left floating, NO_CPU VID codes of 11111XX for VR10 and 0000000X, 1111111X
for VR11 will set both the VID Fault Latch and the Fault Latch to disable the error amplifier. The controller will be
latched OFF and a power-on reset (POR) must be performed to produce a new soft start sequence. In these 2
modes, the NO_CPU codes are ignored during startup. See Table 1 for further details.
When VIDSEL is connected to GND via a 6.49K resistor, NO_CPU VID codes of 11111 will set the Fault Latch to
disable the error amplifier but the VID Fault Latch will not be set. The controller will not be latched OFF and a
soft start sequence will be produced when the NO_CPU code is removed and the SS/DEL voltage falls below
0.215V. In Opteron/Athlon64 mode, the NO_CPU codes are not ignored during startup. See Table 1 for further
details.
A 1.3µs delay is provided to prevent a NO_CPU fault condition from occurring during Dynamic VID changes.
VR_RDY (Power Good) Output
The VRRDY pin is an open-collector output and should be pulled up to a voltage source through a resistor.
During soft start, the VRRDY remains low until the output voltage is in regulation and SS/DEL is above 3.77V.
The VRRDY pin becomes low if the fault latch is set. A high level at the VRRDY pin indicates that the converter is
in operation and has no fault, but does not ensure the output voltage is within the specification. Output voltage
regulation within the design limits can logically be assured however, assuming no component failure in the
system.
Load Current Indicator Output
The VDRP pin voltage represents the average phase current of the converter plus the DAC voltage. The load
current can be retrieved by subtracting the VDAC voltage from the VDRP voltage.
Page 23 of 47
9/14/2005

Related parts for IR3084UMTRPBF