DW025ABK-M Lineage Power, DW025ABK-M Datasheet - Page 11

no-image

DW025ABK-M

Manufacturer Part Number
DW025ABK-M
Description
CONV DC/DC +5/+-12V 25W OUT
Manufacturer
Lineage Power
Series
DW025r
Type
Isolated with Remote On/Offr
Datasheet

Specifications of DW025ABK-M

Output
5V, ±12V
Number Of Outputs
3
Power (watts)
25W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
9-DIP Module
1st Output
5 VDC @ 5A
2nd Output
12 VDC @ 1A
3rd Output
-12 VDC @ 1A
Size / Dimension
2.80" L x 2.40" W x 0.50" H (71.1mm x 61mm x 12.7mm)
Power (watts) - Rated
25W
Operating Temperature
-40°C ~ 100°C
Efficiency
82%
Approvals
CE, CSA, UL, VDE
Product
Isolated
Output Power
25 W
Input Voltage Range
36 V to 75 V
Output Voltage (channel 1)
5 V
Output Current (channel 1)
5 A
Output Voltage (channel 2)
12 V
Output Current (channel 2)
1 A
Output Voltage (channel 3)
- 12 V
Output Current (channel 3)
1 A
Isolation Voltage
500 V
Package / Case Size
DIP
Output Type
Isolated
Output Voltage
5 V
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Data Sheet
April 2008
Test Configurations
Figure 19. Output Noise Measurement Test Setup
Figure 20. Triple Output Voltage and Efficiency
Lineage Power
Note: Use the specified ceramic capacitor. Scope measurement
Note: All measurements are taken at the module terminals. When
SUPPLY
V
RESISTANCE
O2
should be made by using a BNC socket. Position the load
between 50 mm (2 in.) and 75 mm (3 in.) from the module.
CONTACT
socketing, place Kelvin connections at module terminals to
avoid measurement errors due to socket contact resistance.
V
V
V
V
, V
O2
O3
O1
O1
COM
O3
(–)
(–)
=
(+)
(+)
,
Measurement Test Setup
j
---------------------------------------------------------------
I
I
=
3
1
V
I
V
+
V
V
SENSE
Oj
V
I
I
(+)
(–)
COPPER STRIP
O1
SENSE
V
O3
(+)
+
+
(–)
V
V
SENSE
V
O2,
COM
I
0.47 µF
0.1 µF
0.47 µF
COM
V
(continued)
SENSE
V
O3
V
V
V
V
V
O2
COM
O2
O3
O1
O1
O1
, V
(+)
(+)
(+)
(–)
(–)
SENSE
V
O3
I
O2
I
I
Oj
(+)
I
I
I
DISTRIBUTION LOSSES
O 2
O 3
O 1
100
SCOPE
SCOPE
SCOPE
CONTACT AND
R
R
R
LOAD2
LOAD1
LOAD3
8-810(C).c
8-749(C).c
LOAD2
LOAD3
LOAD1
CW025 Triple-Output-Series Power Modules:
Design Considerations
Input Source Impedance
The power module should be connected to a low
ac-impedance input source. Highly inductive source im-
pedances can affect the stability of the power module. A
33 µF electrolytic capacitor (ESR < 0.7
mounted close to the power module helps to ensure the
stability of the unit.
Safety Considerations
For safety-agency approval of the system in which the
power module is used, the power module must be
installed in compliance with the spacing and separation
requirements of the end-use safety agency standard,
i.e., UL -1950, CSA 22.2-950, and EN60950.
For the converter output to be considered meeting the
requirements of safety extra-low voltage (SELV), one of
the following must be true:
If the input meets extra-low voltage (ELV) requirements,
then the converter’s output is considered ELV.
The input to these units is to be provided with a maxi-
mum 5 A normal-blow fuse in the ungrounded lead.
All inputs are SELV and floating, with the output also
floating.
All inputs are SELV and grounded, with the output
also grounded.
Any non-SELV input must be provided with reinforced
insulation from any other hazardous voltages, includ-
ing the ac mains, and must have a SELV reliability
test performed on it in combination with the convert-
ers. Inputs must meet SELV requirements.
36 Vdc to 75 Vdc Input; 25 W
at 100 kHz)
11

Related parts for DW025ABK-M