AXB030X43-SRZ Lineage Power, AXB030X43-SRZ Datasheet - Page 13

CONVERTER DC/DC 3-6V 30W SMD

AXB030X43-SRZ

Manufacturer Part Number
AXB030X43-SRZ
Description
CONVERTER DC/DC 3-6V 30W SMD
Manufacturer
Lineage Power
Series
Austin Lynx™r
Type
Point of Load (POL) Non-Isolated with Remote On/Offr
Datasheets

Specifications of AXB030X43-SRZ

Output
3 ~ 6V
Number Of Outputs
1
Power (watts)
30W
Mounting Type
Surface Mount
Voltage - Input
18 ~ 30V
Package / Case
6-SMD Module
1st Output
3 ~ 6 VDC @ 10A
Size / Dimension
1.30" L x 0.53" W x 0.33" H (33mm x 13.5mm x 8.3mm)
Power (watts) - Rated
30W
Operating Temperature
-40°C ~ 85°C
Efficiency
91%
Approvals
CSA, EN, UL, VDE
Output Power
60 W
Input Voltage Range
18 V to 30 V
Output Voltage (channel 1)
3 V to 6 V
Output Current (channel 1)
10 A
Package / Case Size
SMD
Output Type
Non-Isolated
Output Voltage
3 V to 6 V
Product
Non-Isolated / POL
Output Current
10A
Input Voltage
24V
Screening Level
Industrial
Product Length (mm)
33mm
Product Depth (mm)
13.46mm
Mounting Style
Surface Mount
Pin Count
6
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
555-1106-2
CC109106738
Wind Tunnel
Data Sheet
December 18, 2009
Thermal Considerations
Power modules operate in a variety of thermal
environments; however, sufficient cooling should always
be provided to help ensure reliable operation.
Considerations include ambient temperature, airflow,
module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of
the module will result in an increase in reliability. The
thermal data presented here is based on physical
measurements taken in a wind tunnel. The test set-up
is shown in Figure 32. Note that the airflow is parallel to
the long axis of the module as shown in figure 32. The
derating data applies to airflow in either direction of the
module’s long axis.
LINEAGE
PWBs
POWER
Figure 32. Thermal Test Set-up.
flow
Air
(0.50)
x
12.7_
(3.0)
76.2_
25.4_
(1.0)
18/20– 30/32Vdc input; 3 – 6Vdc & 5 – 15Vdc Output; 30/50W
Probe Location
for measuring
airflow and
ambient
temperature
Power Module
Austin Lynx
The thermal reference point, T
specifications is shown in Figure 33. For reliable
operation this temperature should not exceed 125
The output power of the module should not exceed the
rated power of the module (Vo,set x Io,max).
Please refer to the Application Note “Thermal
Characterization Process For Open-Frame Board-
Mounted Power Modules” for a detailed discussion of
thermal aspects including maximum device
temperatures.
Figure 33. T ref Temperature measurement location.
TM
24V: Non-isolated Power Modules:
ref
used in the
o
C.
13