LK5660-7R POWER ONE, LK5660-7R Datasheet

CONVERTER AC/DC 225VIN 48VOUT

LK5660-7R

Manufacturer Part Number
LK5660-7R
Description
CONVERTER AC/DC 225VIN 48VOUT
Manufacturer
POWER ONE
Series
Kr
Datasheet

Specifications of LK5660-7R

Voltage - Output
24V
Number Of Outputs
2
Power (watts)
150W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 255VAC
Mounting Type
Chassis Mount
1st Output
24 VDC @ 3A
2nd Output
24 VDC @ 3A
Size / Dimension
6.63" L x 4.37" W x 3.15" H (168.5mm x 111mm x 80mm)
Power (watts) - Rated
150W
Operating Temperature
-25°C ~ 71°C
Efficiency
83%
Approvals
CE, cUL, EN, TUV
Output Voltage (channel 1)
24 V
Output Current (channel 1)
3 A
Output Voltage (channel 2)
24 V
Output Current (channel 2)
3 A
Isolation Voltage
2.8 KV
Output Type
Isolated
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
LK 5660-7R
LK 5660-7R
Q1660869
Description
The LK 4000/5000 Series of AC-DC converters represents
a flexible range of power supplies for use in advanced
electronic systems; the LKP models are an extension with
increased output power, but optimized to 230 VAC.
Features include full power factor correction, good hold-up
time, high efficiency and reliability, low output noise, and
excellent dynamic response to load/line changes.
The converters are protected against surges and
transients occurring at the source lines. Input over- and
undervoltage lockout circuitry disables the outputs, when
the input voltage is outside of the specified range. Input
inrush current limitation is included for preventing circuit
breakers and fuses from tripping at switch-on.
All outputs are overload, open- and short-circuit proof, and
protected by a built-in suppressor diode. The outputs can
be inhibited by a logic signal applied to connector pin 18. If
the inhibit function is not used, pin 18 must be connected
with pin 14 to enable the outputs.
Table of Contents
Description ...................................................................... 1
Model Selection ............................................................... 2
Functional Description .................................................... 4
Electrical Input Data ........................................................ 5
Electrical Output Data ..................................................... 8
Auxiliary Functions ........................................................ 13
BCD20001-G Rev AC, 16-Dec-2010
80
3.2"
16 TE
168
6.6"
111
4.4"
3 U
Page
Page 1 of 29
LED indicators display the status of the converter and
allow visual monitoring of the system at any time.
Full input to output, input to case, output to case and
output to output isolation is provided. The converters are
designed and built according to the international safety
standards IEC/EN 60950-1 2
approved by the safety agencies TÜV and CSA (for USA
and Canada).
The case design allows operation at nominal load up to
71 °C in a free air ambient temperature. If forced cooling is
provided, the ambient temperature may exceed 71 °C, but
the case temperature must remain below 95 °C under all
conditions. However, higher output power up to 280 W is
possible depending on environmental conditions and
converter model.
An internal temperature sensor generates an inhibit signal,
which disables the outputs, when the case temperature T
exceeds the limit. The outputs automatically recover, when
Electromagnetic Compatibility (EMC) .......................... 16
Environmental Conditions ............................................ 17
Mechanical Data ........................................................... 18
Safety and Installation Instructions .............................. 20
Description of Options .................................................. 22
Accessories .................................................................. 28
Features
• RoHS lead-free-solder and lead-solder-exempted
• Class I equipment
• Power factor >0.93, harmonics IEC/EN 61000-3-2
• Immunity according to IEC/EN 61000-4-2, -3, -4, -5, -6
• High efficiency
• Input over- and undervoltage lockout
• Adjustable output voltage with remote on/off
• 1 or 2 outputs: SELV, no load, overload, and short-
• Rectangular current limiting characteristic
• Immunity accord. to IEC 61000-4-2, -3, -4, -5, -6
• PCBs protected by lacquer
• Very high reliability
Safety-approved to IEC/EN 60950-1 and UL/CSA
60950-1 2
products are available.
circuit proof
150 – 280 Watt AC-DC Converters
K Series with PFC Data Sheet
nd
Ed.
nd
Ed. They have been
www.power-one.com
Page
C

Related parts for LK5660-7R

LK5660-7R Summary of contents

Page 1

U 80 168 3.2" 6.6" Description The LK 4000/5000 Series of AC-DC converters represents a flexible range of power supplies for use in advanced electronic systems; the LKP models are an extension with increased output ...

Page 2

... V i min i max [VAC] 85 – 264 LK4002-7R LK4003-6R 85 – 264 LK4301-7R LK4501-7R LK4601-7R 85 – 264 LK5320-7R LK5540-7R LK5660-7R 187 – 255 LKP5320-6R LKP5660-7R LKP5661- °C. Typical values are approximately 2% better. A Operating input range Type designation V – min i max [VAC] 85 – 264 ...

Page 3

Part Number Description Operating input voltage – 264 VAC ............................................................ LK 187 – 255 VAC ........................................................ LKP Number of outputs (4 = single double) ................... 4, 5 Single-output models: Nominal voltage output 1 (main ...

Page 4

Functional Description The input voltage is fed via an input fuse, an input filter, a rectifier, and an inrush current limiter to a boost converter. This step-up converter provides a sinusoidal input current (IEC/EN 61000-3-2, class D equipment) and charges ...

Page 5

Electrical Input Data General Conditions: – °C, unless T is specified – Pin 18 connected to pin 14, R input not connected, V – Sense line pins S+ and S– connected to Vo+ and Vo–, ...

Page 6

I [A] inr 100 LKP 0.1 0.5 Fig. 4 Theoretical worst case input inrush current versus time 255 for models without i ext option ...

Page 7

Switching Frequency Fig. 9 Typical switching frequency of the DC/DC converter versus load (The boost converter at the input stage operates with a constant switching frequency of 100 kHz.) Hold-up Time ms 160 V = 230 V i 120 80 ...

Page 8

Electrical Output Data General Conditions: – °C, unless T is specified – Pin 18 (i) connected to pin 14 (S– or Vo1–), R input not connected, V – Sense line pins 12 (S+) and 14 ...

Page 9

... nom 12 70 – V ±12 i max –40 – nom , ±100 ±150 nom 0.3 – T ±0.02 C max LK5660 / 5740 25.68 V Output 1 Output 2 min typ max min typ max 23.86 24.14 23.64 o nom 7 7 28.5/34 28.5/34 – 2 2.7 i max – max – ...

Page 10

Table 7a: Output data of double-output LKP models. General conditions as in table 5. Model Nom. output voltage Characteristics Conditions V Output voltage nom V Overvoltage protection (suppressor diode Output current nom. ...

Page 11

Thermal Considerations If a converter is located in free, quasi-stationary air (convection cooling) at the indicated maximum ambient temperature T (see table: Temperature specifications) A max and is operated at its nominal input voltage and output power, the temperature measured ...

Page 12

Output Voltage Regulation The following figures apply to single-output or double-out- put models with parallel-connected outputs nom 0.98 0.5 0 0.5 Fig. 13 Typical output characteristic V versus ±1% od ...

Page 13

Auxiliary Functions Inhibit for Remote On/Off The outputs may be enabled or disabled by means of a logic signal (TTL, CMOS, etc.) applied between the inhibit input i (pin 18) and pin 14 (S– or Vo1–). In systems with several ...

Page 14

Notes: – The R-Function excludes option P (output voltage adjustment by potentiometer). If the output voltages are increased above V control, option P setting, remote sensing, or option T, the output currents should be reduced, so that P exceeded. – ...

Page 15

Display Status of LEDs V > 0.95 to 0.98V o1 o1 adj min i max V > 0.95 to 0.98V o1 o1 adj ...

Page 16

Electromagnetic Compatibility (EMC) A metal oxide VDR together with an input fuse and an input filter form an effective protection against high input Immunity Table 11: Electromagnetic immunity (type tests) Phenomenon Standard Level Electrostatic IEC discharge 61000-4-2 (to ...

Page 17

TÜV-Divina, ESVS 30:R&S, BBA 9106/UHALP 9107:Schwarzb., QP, 2005-11-11 Testdistance 10 m, LK4301-7R =230 VAC = 100 200 Fig. 27 Typ. radiated emissions ...

Page 18

Reliability Table 14: MTBF calculated according to MIL-HDBK 217F Values at specified Model case temperature MTBF LK4301-7ER Mechanical Data Dimensions in mm. The converters are designed to be inserted into a 19" rack, 160 mm long, according to IEC 60297-3. ...

Page 19

Fig. 29 Option B1: Aluminium case K02 with small cooling plate; black finish (EP powder coated). Suitable for mounting with access from the backside. Total weight approx. 1.2 kg. Note: Long case with option B2, elongated by ...

Page 20

Safety and Installation Instructions Connector Pin Allocation The connector pin allocation table defines the electrical potentials and the physical pin positions on the H15 connector. The protective earth is connected by a leading pin (no. 24), ensuring that it makes ...

Page 21

An additional external fuse, suitable for the application, might be necessary in the wiring to the other line input if: • Local requirements demand an individual fuse in each source line • Phase and ...

Page 22

Safety of Operator-Accessible Output Circuits If the output circuit of a converter is operator-accessible, it shall be an SELV circuit according to IEC/EN 60950. The table below shows a configuration, compliance with which causes the output circuit ...

Page 23

Note: Subsequent switch-on cycles at start-up are limited to max. 10 cycles during the first 20 seconds (cold converter) and then to max. 1 cycle every 8 s. Table 20: Inrush current characteristics with option E Characteristics V = 230 ...

Page 24

Table 21: Undervoltage monitoring functions Output type Monitoring 4 JFET NPN yes D3 D7 yes yes DD yes 1 Threshold level adjustable by potentiometer. See Output Data ...

Page 25

Table 24: D-output logic signals Version of D D1, D2, D3, D4, D0 D5, D6, D7, D8, D9, DD Input voltage monitoring V NPN high low high I D ...

Page 26

V ACFAIL Signal (VME) Available only for models with This option defines an undervoltage monitoring circuit for the input and main output voltage. It generates the ACFAIL signal (V signal) according to the VME standard. ...

Page 27

After the ACFAIL signal has gone low, the VME standard requires a hold-up time least 4 ms before the 5 output drops at full load to 4.875 V. This hold-up time t provided by the ...

Page 28

Accessories A variety of electrical and mechanical accessories are available including: – Front panels for 19" DIN-rack: Schroff [HZZ00831] and 16 TE /6U [HZZ00832], or Intermas 16 TE /3U [HZZ00731] – Mating connectors H15, H15S2, and ...

Page 29

Cable connector housing (cable hood) KSG-H15/ H15S4 [HZZ00141] as screw version. Also available as retention clip version [HZZ00142 fully metallic housing. – Wall-mounting plate K02 [HZZ01213] for models with option B1 – Additional external input and ...