LK5660-7R POWER ONE, LK5660-7R Datasheet - Page 10

CONVERTER AC/DC 225VIN 48VOUT

LK5660-7R

Manufacturer Part Number
LK5660-7R
Description
CONVERTER AC/DC 225VIN 48VOUT
Manufacturer
POWER ONE
Series
Kr
Datasheet

Specifications of LK5660-7R

Voltage - Output
24V
Number Of Outputs
2
Power (watts)
150W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 255VAC
Mounting Type
Chassis Mount
1st Output
24 VDC @ 3A
2nd Output
24 VDC @ 3A
Size / Dimension
6.63" L x 4.37" W x 3.15" H (168.5mm x 111mm x 80mm)
Power (watts) - Rated
150W
Operating Temperature
-25°C ~ 71°C
Efficiency
83%
Approvals
CE, cUL, EN, TUV
Output Voltage (channel 1)
24 V
Output Current (channel 1)
3 A
Output Voltage (channel 2)
24 V
Output Current (channel 2)
3 A
Isolation Voltage
2.8 KV
Output Type
Isolated
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
LK 5660-7R
LK 5660-7R
Q1660869
Table 7a: Output data of double-output LKP models. General conditions as in table 5.
Table 7b: Other LKP models
All data not specified in this table are equal to LKP5740-7. General conditions as in table 5.
BCD20001-G Rev AC, 16-Dec-2010
Model
Nom. output voltage
Characteristics
V
V
I
I
v
v
t
Model
Nom. output voltage
Characteristics
I
I
T
1
2
3
o nom
oL
o nom
oL
o
o d
d
A max
o
o BR
V
V
v o
1
2
3
4
5
6
7
6
Both outputs series connected
All other data see LKP5660-7
All other data see LKP5740-7 (battery charger)
o u
o I
Same conditions for both outputs
If the output voltages are increased above V
currents should be reduced accordingly so that P
Measured according to IEC/EN 61204 with a probe according to annex A
See Dynamic Load Regulation
For battery charger applications, a defined negative temperature coefficient can be provided by using a temperature sensor
(see Accessories), but we recommend choosing special battery charger models.
Especially designed for battery charging using the battery temperature sensor (see Accessories). Similar models see table 7b.
V
Breakdown voltage of the incorporated suppressor diodes (1 mA). To exceed V
See Output Voltage Regulation of Double-Output Models
o1
Output voltage
Overvoltage protection
(suppressor diode)
Output current nom.
Output current limit
Output Low frequency V
noise
Static line regulation
with respect to V
Static load regulation
Dynamic Voltage
load
regulat.
Temperature coefficient T
of output voltage
Output current nom
Output current limit
Max. operating temp.
is set to 25.68 V ±1% (R-input open).
3
3
T
Switching freq. BW = 20 MHz
Total incl. spikes
(0.1
Recovery time
C min
deviation
1) I
T
i nom
6
C max
o nom
1
4
.
8
2
4
Conditions
V
T
V
Conditions
V
V
V
V
I
V
V
I
I
o nom
o nom
o nom
C min
i min
i min
i nom
i min
i min
i nom
i min
i nom
i nom
C min
, I
, I
V
V
o nom
V
V
o nom
V
T
T
i max
i max
1
i max
i max
i max
C max
/
C max
2
I
o nom
1
o nom
min typ max min typ max min typ max min typ
23.86
28.5
min
10.2
5.3
Output 1
o nom
via R-input control, option P setting, remote sensing or option T, the output
Output 1
±0.02
±150
7
120
5.2
0.3
10
20
typ
10
is not exceeded.
Page 10 of 29
24.14
LKP5660-7
– 60
±10
max min typ max
LKP 5320-6
2
60
2
7
24 V
23.64
28.5
12 V
5.3
10.2
Output 2
Output 2
±150
7
5.2
10
20
40
150 – 280 Watt AC-DC Converters
5
5
10
24.36
K Series with PFC Data Sheet
o BR
7
34
25.42
4.6
min
6.0
is dangerous for the suppressor diodes.
Output 1
LKP5661-5
Output 1, 2
±0.02
2
±150
120
4.5
0.4
10
20
typ
5.8
24 V
LKP5740-7
2
25.94 25.17
– 80
±10
max min
25.68 V
2
50
34
4.6
5.2
Output 2
7
LKP5741-5
Output 1, 2
2
±150
100
www.power-one.com
4.5
10
20
5
5
25.68 V
typ
5
26.19
max
max
3
50
mV
Unit
%/K
mV
ms
Unit
V
A
°C
A
pp

Related parts for LK5660-7R